Buying more than 2? Email us for a discount: support@bottlefillingstations.com

FREE SHIPPING

All Products. No Minimums. 

Zurn Wilkins  |  SKU: 2-975XL2

Wilkins 2-975XL2 | 2" Reduced Pressure Principle Backflow Preventer

Regular price $ 2,212.99

Shipping

🚚✨ Free Shipping in the Continental U.S. 
All Products. No Minimums.


Estimated Shipping Times:


Important Note on Delivery Times

All shipping estimates provided are approximate only. While we always strive to meet or exceed your delivery expectations, we cannot guarantee the exact delivery times listed.

For time-sensitive orders, please contact us directly so we can provide a more accurate lead time estimate based on your specific requirements.

Same Day Shipping

All in stock orders received before 3PM EST will ship the same day. Orders received after 3PM EST will ship the following business day. 

Water Filters, Hand Dryers, & Indoor Bottle Fillers are our most popular in stock items. 

Outdoor Tubular Drinking Fountains

Evergreen normally ships in 5-15 days. Black, Gray and Blue ship in 2-4 weeks. 

Ice Machines

In stock units ship within 48 hours. Other units normally ship in 2-4 weeks.

Other

Orders that ship directly from a manufacturer normally have a firm shipping estimate but those dates are subject to change due to manufacturer production, inventory or shipping. We do our best to estimate ship dates but orders shipping directly from the manufacturer can have unexpected delays. We will confirm tracking information when orders ship directly from a manufacturer but may not have updates or estimates beyond the original estimate. Once your order is placed with the manufacturer, it may not be able to be cancelled even if it hasn't shipped yet.  

Please contact support@bottlefillingstations.com to confirm delivery time for a specific product or quantity. Or to inquire about an existing order. 


Special Case Shipping Rates

 

Please note that shipping rates are subject to change at any time.  We reserve the right to charge an additional fee in addition to the regularly advertised shipping fee for shipping to remote areas not easily accessible by typical freight carrier means (i.e. islands only accessible by ferry). If your order falls into this category, you will be notified upon receipt of your order, and have the option to complete the purchase with additional fee or to cancel the order.  Please note, these instances are very rare, as most locations are reachable by regular freight. If you have any questions, please contact us! 


Key Terms & Conditions

 

Exceptions may apply to islands and other remote territories.

All orders shipped by the carrier of our choice.  

 

 

 


 

 

 

NOTICE: Product images may vary from the actual item due to differences in size or configuration options.

The Wilkins 2‑975XL2 is a 2‑inch reduced pressure principle assembly designed to protect potable water systems from backsiphonage and backpressure contamination. This 975xl2 backflow preventer is part of the trusted Zurn Wilkins 975xl2 product line, engineered for high‑hazard protection in commercial and residential applications. The Zurn‑975xl2 model meets modern lead‑free standards and provides reliable performance with easy maintenance access.


Key Specifications:

Size 2 Inches
Maximum Water Pressure 175 PSI
Maximum Water Temperature 180°F
Notable Certifications ASSE 1013, cUPC, CSA B64.4, AWWA C511, NSF/ANSI/CAN 61 & 372
End Connections Threaded ANSI B1.20.1


Features & Benefits:

  • High Hazard Protection: ASSE 1013 listed for protection against both backsiphonage and backpressure where a potential health hazard exists in potable water systems.
  • Lead‑Free Compliance: Certified to NSF/ANSI/CAN 61 and 372 with less than 0.25% weighted average lead content.
  • Easy Maintenance Access: First and second check valves are accessible without removing the relief valve or the entire device from the line.
  • Optional Flood Detection: Configurable with a relief valve sensor (MS suffix) that detects and signals excessive water discharge for property damage prevention.


Other Related Variants:


What's Included:

  • Main valve body: Low Lead Cast Bronze ASTM B 584
  • Access covers: Low Lead Cast Bronze ASTM B 584
  • Fasteners: Stainless Steel, 300 Series
  • Elastomers: Silicone and Buna Nitrile
  • Polymers: Noryl™
  • Springs: Stainless Steel, 300 Series
  • Ball valve handles: Stainless Steel


FAQ


Q: What Is the Difference Between the Wilkins 2‑975XL2 and the Standard 975XL Model?
A: The Wilkins 2‑975XL2 is the lead‑free version certified to NSF/ANSI/CAN 61 and 372, containing less than 0.25% weighted average lead content, making it compliant with potable water regulations.

Q: Does the 2‑975XL2 Require an Air Gap for Indoor Installations?
A: Yes. If installed indoors, the assembly must be supplied with an air gap adapter (Model AG) to ensure proper drainage and prevent submersion.

Q: Can Maintenance Be Performed Without Removing the Assembly?
A: Yes. The zurn‑975xl2 design allows in‑line maintenance with the first and second check valves accessible without removing the relief valve or disconnecting the entire assembly.

Q: What Applications Commonly Use the 975XL2 Backflow Preventer?
A: The 975xl2 backflow assembly is widely used in potable water lines for commercial, industrial, and residential systems where protection against backsiphonage and backpressure is required.

Q: Is the Wilkins Zurn 975XL2 Available in Other Sizes?
A: Yes. The wilkins zurn 975xl2 product line includes ¾", 1", 1¼", 1½", and 2" sizes to accommodate different system requirements.

Q: What Optional Accessories Are Available?
A: Accessories include air gap (Model AG), repair kits, thermal expansion tank (XT), soft‑seated check valve (40XL2), shock arrester (1260XL), and relief valve monitoring retrofit kit (RFK‑975XL2MS).


NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.