Zurn Wilkins  |  SKU: 114-600XLHR

Wilkins 114-600XLHR | Water Pressure Reducing Valve, 1 1/4 Inches

Regular price $ 987.99

Shipping

🚚✨ Free Shipping in the Continental U.S. 
All Products. No Minimums.


Estimated Shipping Times:


Important Note on Delivery Times

All shipping estimates provided are approximate only. While we always strive to meet or exceed your delivery expectations, we cannot guarantee the exact delivery times listed.

For time-sensitive orders, please contact us directly so we can provide a more accurate lead time estimate based on your specific requirements.

Same Day Shipping

All in stock orders received before 3PM EST will ship the same day. Orders received after 3PM EST will ship the following business day. 

Water Filters, Hand Dryers, & Indoor Bottle Fillers are our most popular in stock items. 

Outdoor Tubular Drinking Fountains

Evergreen normally ships in 5-15 days. Black, Gray and Blue ship in 2-4 weeks. 

Ice Machines

In stock units ship within 48 hours. Other units normally ship in 2-4 weeks.

Other

Orders that ship directly from a manufacturer normally have a firm shipping estimate but those dates are subject to change due to manufacturer production, inventory or shipping. We do our best to estimate ship dates but orders shipping directly from the manufacturer can have unexpected delays. We will confirm tracking information when orders ship directly from a manufacturer but may not have updates or estimates beyond the original estimate. Once your order is placed with the manufacturer, it may not be able to be cancelled even if it hasn't shipped yet.  

Please contact support@bottlefillingstations.com to confirm delivery time for a specific product or quantity. Or to inquire about an existing order. 


Special Case Shipping Rates

 

Please note that shipping rates are subject to change at any time.  We reserve the right to charge an additional fee in addition to the regularly advertised shipping fee for shipping to remote areas not easily accessible by typical freight carrier means (i.e. islands only accessible by ferry). If your order falls into this category, you will be notified upon receipt of your order, and have the option to complete the purchase with additional fee or to cancel the order.  Please note, these instances are very rare, as most locations are reachable by regular freight. If you have any questions, please contact us! 


Key Terms & Conditions

 

Exceptions may apply to islands and other remote territories.

All orders shipped by the carrier of our choice.  

 

 

 


 

 

 

The Wilkins 114-600XLHR is a water pressure reducing valve with integral by-pass check valve and strainer, designed for residential and commercial potable water systems requiring reliable pressure regulation and thermal expansion protection.

 

Key Specifications:

  • Size: 1 1/4 Inches
  • Maximum Working Water Pressure: 300 psi
  • Maximum Working Water Temperature: 140°F
  • Notable Certifications: ASSE 1003, IAPMO, CSA
  • Connection Type: Single Union FNPT

 

Other Related Variants:

  • 112-600XLHR: 1 1/2 Inches size
  • 12-600XLHR: 1 Inches size
  • 1-600XLHR: Unknown size variant
  • 2-600XLHR: 2 Inches size
  • 34-600XLHR: 3/4 Inches size

 

Materials:

  • Main valve body and access covers: Low Lead Cast Bronze ASTM B 584
  • Access covers: Low Lead Brass
  • Fasteners: Stainless Steel, 300 Series
  • Stem and plunger: Low Lead Cast Bronze ASTM B 584 / Low Lead Brass
  • Elastomers: Buna Nitrile (FDA Approved)
  • Elastomers: EPDM (FDA Approved)
  • Cap gaskets: Natural Vulcanized Fibre
  • Cap gaskets: Acetal (Delrin™)
  • Strainer screen: Stainless Steel, 300 Series
  • Seat: Stainless Steel, 300 Series

 

Typical Installation:

Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted in accordance with the latest edition of the Uniform Plumbing Code. The Zurn 114-600XLHR may be installed in any position. If installed in a pit, vault or inside application, specify the "SC" sealed cage option. Multiple installations are recommended for wide demand variations or where the desired pressure reduction is more than 4 to 1 (i.e.: 200 psi inlet reduced to 50 psi outlet). Anytime a reducing valve is adjusted, a pressure gauge must be used downstream to verify correct pressure setting. Do not bottom adjustment bolt on bell housing.

 

Standards Compliance:

ASSE Listed 1003; IAPMO Listed; CSA Certified; City of Los Angeles Approved; NSF/ANSI/CAN 61

 

Features & Benefits:

  • High Pressure Range: The 114-600XLHR features an HR option with 75 psi to 125 psi spring range, factory set at 85 psi, ideal for applications requiring elevated outlet pressures.
  • Thermal Expansion Protection: Direct acting integral by-pass design prevents buildup of excessive system pressure caused by thermal expansion, protecting the plumbing system.
  • Easy Maintenance: Integral strainer with separate access covers for plunger and strainer screen allows for frequent cleaning without removing valve from line, reducing downtime.
  • Balanced Piston Design: Provides smooth and responsive reaction to changes in system flow demand while protecting from inlet pressure changes for consistent outlet pressure.

 

FAQ

 

Q: What is the difference between the standard 600XL and the 114-600XLHR model?

A: The HR option provides a higher spring range of 75 psi to 125 psi and is factory set at 85 psi, compared to the standard 25 psi to 75 psi range set at 50 psi, making it suitable for applications requiring elevated outlet pressures.

Q: Can the Zurn 114-600XLHR be installed in any orientation?

A: Yes, the Wilkins 114-600XLHR may be installed in any position. However, if installed in a pit, vault, or inside application, the "SC" sealed cage option should be specified for optimal performance and maintenance access.

Q: What pressure reduction ratio is recommended for this valve?

A: Multiple installations are recommended for wide demand variations or where the desired pressure reduction exceeds a 4:1 ratio. For example, reducing 200 psi inlet to 50 psi outlet approaches this limit. Always use a downstream pressure gauge when adjusting.

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.