Buying more than 2? Email us for a discount: support@bottlefillingstations.com

FREE SHIPPING

All Products. No Minimums. 

Zurn Wilkins  |  SKU: RK1-720APK

Wilkins RK1-720APK | Model 720A Pressure Vacuum Breaker Repair Kit

Regular price $ 93.99

Shipping

🚚✨ Free Shipping in the Continental U.S. 
All Products. No Minimums.


Estimated Shipping Times:


Important Note on Delivery Times

All shipping estimates provided are approximate only. While we always strive to meet or exceed your delivery expectations, we cannot guarantee the exact delivery times listed.

For time-sensitive orders, please contact us directly so we can provide a more accurate lead time estimate based on your specific requirements.

Same Day Shipping

All in stock orders received before 3PM EST will ship the same day. Orders received after 3PM EST will ship the following business day. 

Water Filters, Hand Dryers, & Indoor Bottle Fillers are our most popular in stock items. 

Outdoor Tubular Drinking Fountains

Evergreen normally ships in 5-15 days. Black, Gray and Blue ship in 2-4 weeks. 

Ice Machines

In stock units ship within 48 hours. Other units normally ship in 2-4 weeks.

Other

Orders that ship directly from a manufacturer normally have a firm shipping estimate but those dates are subject to change due to manufacturer production, inventory or shipping. We do our best to estimate ship dates but orders shipping directly from the manufacturer can have unexpected delays. We will confirm tracking information when orders ship directly from a manufacturer but may not have updates or estimates beyond the original estimate. Once your order is placed with the manufacturer, it may not be able to be cancelled even if it hasn't shipped yet.  

Please contact support@bottlefillingstations.com to confirm delivery time for a specific product or quantity. Or to inquire about an existing order. 


Special Case Shipping Rates

 

Please note that shipping rates are subject to change at any time.  We reserve the right to charge an additional fee in addition to the regularly advertised shipping fee for shipping to remote areas not easily accessible by typical freight carrier means (i.e. islands only accessible by ferry). If your order falls into this category, you will be notified upon receipt of your order, and have the option to complete the purchase with additional fee or to cancel the order.  Please note, these instances are very rare, as most locations are reachable by regular freight. If you have any questions, please contact us! 


Key Terms & Conditions

 

Exceptions may apply to islands and other remote territories.

All orders shipped by the carrier of our choice.  

 

 

 


 

 

 

The Wilkins RK1‑720APK Pro‑Kit is a targeted repair solution designed to restore proper sealing and operation in Model 720A Pressure Vacuum Breakers used in irrigation systems. It includes all critical internal components required to maintain compliance and extend service life.


Key Specifications:

Compatible Sizes ½", ¾", 1"
Kit Type Internal component repair kit
Application Irrigation backflow prevention systems
Components Included O‑Ring Bonnet, Load Nut & Guide, Load Washer, Upper Disc, Poppet
Compatibility Model 720A Pressure Vacuum Breaker only


Features & Benefits:

  • Complete Internal Component Set: Provides all five critical wear parts for comprehensive repair.
  • Targeted Repair Solution: Specifically engineered for Model 720A devices in ½", ¾", and 1" sizes.
  • Restores Proper Operation: Replaces worn sealing and moving parts to restore full backflow prevention capability.
  • Cost‑Effective Maintenance: Extends the service life of existing assemblies without requiring full replacement.


Standards Compliance:

Compatible with Model 720A devices meeting ASSE 1020 standards; USC FCCCHR approved assemblies


What's Included:

  • O‑Ring Bonnet
  • Load Nut & Guide
  • Load Washer
  • Upper Disc
  • Poppet
  • Installation instructions


Comparison of Wilkins Repair Kits:

Feature RK1‑720APK (720A PVB) RK34‑375 (375 Series) RK1‑NR3XL (NR3XL Valve)
Capacity Restores 720A assemblies (½"–1") Complete rebuild for 375 Series backflow preventers Repair kit for 1" NR3XL pressure reducing valves
Best For Irrigation systems requiring backflow protection Commercial/industrial backflow prevention assemblies Residential/commercial pressure regulation systems
Key Components Bonnet O‑Ring, Load Nut & Guide, Load Washer, Upper Disc, Poppet Check assemblies, springs, seals, O‑rings Spring, diaphragm, seals, O‑rings
Compliance ASSE 1020, USC FCCCHR ASSE 1013, USC FCCCHR ANSI/ASSE 1003


How to Install the RK1‑720APK:

  1. Shut off water supply by closing inlet and outlet shut‑off valves.
  2. Remove canopy and bonnet from the 720A assembly.
  3. Bleed pressure by opening the No. 2 test cock.
  4. Disassemble internal components (disc & poppet assembly, spring, spider).
  5. Replace worn parts with the new RK1‑720APK kit components.
  6. Reassemble and tighten bonnet and canopy screws securely.
  7. Pressurize and test the assembly according to standard test procedures.


FAQ


Q: What Model 720A Sizes Is the Wilkins RK1‑720APK Compatible With?
A: The RK1‑720APK Pro‑Kit is designed for use with Model 720A Pressure Vacuum Breakers in ½", ¾", and 1" sizes. For example, it is compatible with the Wilkins ½" 720A Pressure Vacuum Breaker Assembly.

Q: What Components Are Included in This Repair Kit?
A: The kit includes five essential parts: O‑Ring Bonnet, Load Nut & Guide, Load Washer, Upper Disc, and Poppet.

Q: When Should I Use the RK1‑720APK Repair Kit?
A: Use this kit when your Model 720A Pressure Vacuum Breaker shows signs of leaking, reduced performance, or fails testing.

Q: What Systems Commonly Use the 720A and This Repair Kit?
A: The 720A is widely used in irrigation backflow prevention setups. Compatible systems include residential and commercial irrigation lines where backsiphonage protection is required.

Q: How Often Should the 720A Be Serviced?
A: Annual inspection and maintenance are required. Internal components should be replaced when wear is evident or if the device fails testing.

Q: Can the RK1‑720APK Be Installed Outdoors?
A: Yes, but the 720A assembly must be protected against freezing conditions. Follow drain procedures or remove internal components during winter.

Q: Is Professional Installation Required?
A: Yes. Backflow preventer repairs should be performed by licensed professionals to ensure compliance with plumbing codes and proper system protection.

Q: What Happens If I Exceed the Recommended Service Interval?
A: Using the cartridge beyond its recommended service interval can result in reduced performance, leaks, or failure to prevent backsiphonage. Timely replacement ensures compliance and safety.


NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.


"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us now

OUR HAPPY CUSTOMERS

Go to Table of Content