Wilkins 38-ZW3870XLT-4P | Aqua-Gard® Thermostatic Mixing Valve, 4-Port
Wilkins 38-ZW3870XLT-4P | Aqua-Gard® Thermostatic Mixing Valve, 4-Port is backordered and will ship as soon as it is back in stock.
Shipping
Shipping
🚚✨ Free Shipping in the Continental U.S.
All Products. No Minimums.
Estimated Shipping Times:
Important Note on Delivery Times
All shipping estimates provided are approximate only. While we always strive to meet or exceed your delivery expectations, we cannot guarantee the exact delivery times listed.
For time-sensitive orders, please contact us directly so we can provide a more accurate lead time estimate based on your specific requirements.
Same Day Shipping
All in stock orders received before 3PM EST will ship the same day. Orders received after 3PM EST will ship the following business day.
Water Filters, Hand Dryers, & Indoor Bottle Fillers are our most popular in stock items.
Outdoor Tubular Drinking Fountains
Evergreen normally ships in 5-15 days. Black, Gray and Blue ship in 2-4 weeks.
Ice Machines
In stock units ship within 48 hours. Other units normally ship in 2-4 weeks.
Other
Orders that ship directly from a manufacturer normally have a firm shipping estimate but those dates are subject to change due to manufacturer production, inventory or shipping. We do our best to estimate ship dates but orders shipping directly from the manufacturer can have unexpected delays. We will confirm tracking information when orders ship directly from a manufacturer but may not have updates or estimates beyond the original estimate. Once your order is placed with the manufacturer, it may not be able to be cancelled even if it hasn't shipped yet.
Please contact support@bottlefillingstations.com to confirm delivery time for a specific product or quantity. Or to inquire about an existing order.
Special Case Shipping Rates
Please note that shipping rates are subject to change at any time. We reserve the right to charge an additional fee in addition to the regularly advertised shipping fee for shipping to remote areas not easily accessible by typical freight carrier means (i.e. islands only accessible by ferry). If your order falls into this category, you will be notified upon receipt of your order, and have the option to complete the purchase with additional fee or to cancel the order. Please note, these instances are very rare, as most locations are reachable by regular freight. If you have any questions, please contact us!
Key Terms & Conditions
Exceptions may apply to islands and other remote territories.
All orders shipped by the carrier of our choice.
The Wilkins 38-ZW3870XLT-4P is a point-of-use thermostatic mixing valve designed for scald prevention at individual fixtures with 4-port configuration for multi-outlet applications.
Key Specifications:
- Size: 3/8 Inches
- Maximum Working Pressure: 145 psi
- Outlet Temperature Range: 95-115°F (35-46°C)
- Notable Certifications: ASSE 1070, cUPC, CSA B125.70
- Flow Rate: 0.06–3.1 GPM
Other Related Variants:
- 38-ZW3870XLT: 3-port standard version (1 Hot in, 1 Cold in, 1 Mixed out)
Materials:
- Low Lead Cast Bronze ASTM B 584 w/Chrome Plating ASTM B 456 Service Condition #2
- Low Lead Brass ASTM B 927 UNS C27450
- Polysufone Piston
- Noryl GFN2 Guide Tube
- 300 Series Stainless Steel Spring
- Viton Seals
- Acetal Co-Polymer Checks
Typical Installation:
The device is designed to be installed at a single outlet. It may be used to supply individual outlets when there is sufficient supply pressure. It is suggested to use ball valves on the hot and cold inlet supplies. Ideal for installation under sinks and sensor faucets.
Standards Compliance:
ASSE Listed 1070; cUPC Listed; CSA Certified B125.70; NSF/ANSI/CAN 61-9 Q≤1 (0.25% MAX. WEIGHTED AVERAGE LEAD CONTENT)
Features & Benefits:
- Scald Protection: Rapid response and precise temperature control with outlet range 95-115°F meets ASSE 1070 requirements for fixtures, sinks, lavatories or bathtubs.
- 4-Port Configuration: The Zurn 38-ZW3870XLT-4P provides both mixed and cold outlets, ideal for multi-outlet applications or individual fixture protection with flexible supply options.
- Ultra Low Flow Compatibility: With minimum flow rating of 0.06 GPM, the Wilkins 38-ZW3870XLT-4P provides proper scald protection when used with ultra low flow faucet aerators.
- Integrated Safety Features: Includes integral check valves and strainer screens on hot and cold supply lines for enhanced reliability and water quality protection.
FAQ
Q: What is the maximum pressure differential allowed between hot and cold inlets?
A: The maximum pressure differential is 15 psi between hot and cold inlets for proper operation.
Q: What is the difference between the 38-ZW3870XLT and 38-ZW3870XLT-4P models?
A: The 38-ZW3870XLT is a 3-port version with one mixed outlet, while the 38-ZW3870XLT-4P is a 4-port version with both mixed and cold outlets for multi-outlet applications.
Q: Does the temperature need to be adjusted after installation?
A: Yes, the temperature must be field set during installation. The valve offers set temperature accuracy of +/- 3°F for precise control.
NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.
"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us
Always consult with a licensed professional and check local codes before installation. For further details, check the Owners Manual.
Contact us at support@bottlefillingstations.com with any questions.