Wilkins 38-ZW1070XLCOMP | Thermostatic Mixing Valve, Point-of-Use Scald Protection
Wilkins 38-ZW1070XLCOMP | Thermostatic Mixing Valve, Point-of-Use Scald Protection is backordered and will ship as soon as it is back in stock.
Shipping
Shipping
🚚✨ Free Shipping in the Continental U.S.
All Products. No Minimums.
Estimated Shipping Times:
Important Note on Delivery Times
All shipping estimates provided are approximate only. While we always strive to meet or exceed your delivery expectations, we cannot guarantee the exact delivery times listed.
For time-sensitive orders, please contact us directly so we can provide a more accurate lead time estimate based on your specific requirements.
Same Day Shipping
All in stock orders received before 3PM EST will ship the same day. Orders received after 3PM EST will ship the following business day.
Water Filters, Hand Dryers, & Indoor Bottle Fillers are our most popular in stock items.
Outdoor Tubular Drinking Fountains
Evergreen normally ships in 5-15 days. Black, Gray and Blue ship in 2-4 weeks.
Ice Machines
In stock units ship within 48 hours. Other units normally ship in 2-4 weeks.
Other
Orders that ship directly from a manufacturer normally have a firm shipping estimate but those dates are subject to change due to manufacturer production, inventory or shipping. We do our best to estimate ship dates but orders shipping directly from the manufacturer can have unexpected delays. We will confirm tracking information when orders ship directly from a manufacturer but may not have updates or estimates beyond the original estimate. Once your order is placed with the manufacturer, it may not be able to be cancelled even if it hasn't shipped yet.
Please contact support@bottlefillingstations.com to confirm delivery time for a specific product or quantity. Or to inquire about an existing order.
Special Case Shipping Rates
Please note that shipping rates are subject to change at any time. We reserve the right to charge an additional fee in addition to the regularly advertised shipping fee for shipping to remote areas not easily accessible by typical freight carrier means (i.e. islands only accessible by ferry). If your order falls into this category, you will be notified upon receipt of your order, and have the option to complete the purchase with additional fee or to cancel the order. Please note, these instances are very rare, as most locations are reachable by regular freight. If you have any questions, please contact us!
Key Terms & Conditions
Exceptions may apply to islands and other remote territories.
All orders shipped by the carrier of our choice.
The Wilkins 38-ZW1070XLCOMP is an Aqua-Gard® thermostatic mixing valve designed for point-of-use scald protection with rapid response rate for safe water temperature control.
Key Specifications:
- Size: 3/8 Inches
- Maximum Working Pressure: 125 psi inlet
- Outlet Temperature Range: 95–115°F maximum
- Notable Certifications: ASSE 1070, cUPC Listed
- Connection Type: Compression connection
Other Related Variants:
- 12-ZW1070XL: 1/2 Inch FNPT model
- 12-ZW1070XLC: 1/2 Inch CU Sweat
- 12-ZW1070XLCPVC: 1/2 Inch CPVC version
- 12-ZW1070XLPEX: 1/2 Inch Barb connection
- 12-ZW1070XLPEXF1960: 1/2 Inch Barb alternative
- 12-ZW1070XLPF: 1/2 Inch push fit
- 1-ZW1070XLC: 1 Inch CU Sweat
- 34-ZW1070XL: 3/4 Inch FNPT model
- 34-ZW1070XLCOMP: 3/4 Inch Compression version
Materials:
- Body: Low Lead Cast Bronze, ASTM B 584 with Chrome Plating ASTM B 456 Service Condition #2
- Internal Brass: Low Lead Brass, ASTM B 927, UNS C27450
- Piston: Polysufone
- Guide Tube: Noryl GFN2
- Spring and Screen: 300 Series Stainless Steel
- Seals: Viton
- Checks: Noryl GFN2
Typical Installation:
The Zurn 38-ZW1070XLCOMP is ideal for point-of-use installation at plumbing fixtures and appliances requiring final control of water temperature. Suitable for individual use applications including sinks, lavatories, bathtubs, and sensor faucets. The device is designed to be installed at a single outlet and may supply individual outlets when sufficient supply pressure is available. Ball valves on hot and cold inlet supplies are recommended.
Standards Compliance:
ASSE Listed 1070; cUPC Listed; CSA Certified B125.70; NSF/ANSI/CAN 61-9 Q≤1 (0.25% MAX. WEIGHTED AVERAGE LEAD CONTENT)
Features & Benefits:
- Scald Protection: Mixes hot and cold water to a safer final temperature of 95-115°F, preventing scalding injuries at point of use.
- Rapid Response Rate: Extremely fast temperature adjustment makes it ideal for installation at fixtures and appliances requiring immediate temperature control.
- Lead-Free Compliance: Meets NSF/ANSI/CAN 61-9 standards with 0.25% maximum weighted average lead content for safe drinking water applications.
- Versatile Configurations: Multiple end connection options available to suit all residential and commercial installation requirements.
FAQ
Q: What is the maximum pressure differential allowed between hot and cold inlets?
A: The maximum pressure differential is 15 psi between the hot and cold water inlets for proper operation of the Wilkins 38-ZW1070XLCOMP.
Q: Does the temperature need to be adjusted after installation?
A: Yes, the temperature must be field set during installation. The set temperature accuracy is +/- 3°F (1.78°C) within the 95-115°F outlet range.
Q: What is the minimum flow rate required for this valve to operate?
A: The Zurn 38-ZW1070XLCOMP has a minimum flow rate of 0.25 gpm and can handle up to 10 gpm at 45 psi pressure loss.
NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.