Zurn Wilkins  |  SKU: 34-NR3XLP

Wilkins 34-NR3XLP | Pressure Reducing Valve with Integral By-Pass & Strainer

Regular price $ 252.99

Shipping

🚚✨ Free Shipping in the Continental U.S. 
All Products. No Minimums.


Estimated Shipping Times:


Important Note on Delivery Times

All shipping estimates provided are approximate only. While we always strive to meet or exceed your delivery expectations, we cannot guarantee the exact delivery times listed.

For time-sensitive orders, please contact us directly so we can provide a more accurate lead time estimate based on your specific requirements.

Same Day Shipping

All in stock orders received before 3PM EST will ship the same day. Orders received after 3PM EST will ship the following business day. 

Water Filters, Hand Dryers, & Indoor Bottle Fillers are our most popular in stock items. 

Outdoor Tubular Drinking Fountains

Evergreen normally ships in 5-15 days. Black, Gray and Blue ship in 2-4 weeks. 

Ice Machines

In stock units ship within 48 hours. Other units normally ship in 2-4 weeks.

Other

Orders that ship directly from a manufacturer normally have a firm shipping estimate but those dates are subject to change due to manufacturer production, inventory or shipping. We do our best to estimate ship dates but orders shipping directly from the manufacturer can have unexpected delays. We will confirm tracking information when orders ship directly from a manufacturer but may not have updates or estimates beyond the original estimate. Once your order is placed with the manufacturer, it may not be able to be cancelled even if it hasn't shipped yet.  

Please contact support@bottlefillingstations.com to confirm delivery time for a specific product or quantity. Or to inquire about an existing order. 


Special Case Shipping Rates

 

Please note that shipping rates are subject to change at any time.  We reserve the right to charge an additional fee in addition to the regularly advertised shipping fee for shipping to remote areas not easily accessible by typical freight carrier means (i.e. islands only accessible by ferry). If your order falls into this category, you will be notified upon receipt of your order, and have the option to complete the purchase with additional fee or to cancel the order.  Please note, these instances are very rare, as most locations are reachable by regular freight. If you have any questions, please contact us! 


Key Terms & Conditions

 

Exceptions may apply to islands and other remote territories.

All orders shipped by the carrier of our choice.  

 

 

 


 

 

 

The Wilkins 34-NR3XLP is a lead-free water pressure reducing valve designed for potable water systems, featuring an integral by-pass check valve and strainer to reduce high inlet pressure while protecting against thermal expansion and debris.

 

Key Specifications:

  • Size: 3/4 Inches
  • Maximum Working Water Pressure: 400 psi
  • Maximum Working Water Temperature: 140°F
  • Notable Certifications: ASSE 1003, NSF/ANSI/CAN 61
  • Connection Type: FNPT union connections

 

Other Related Variants:

  • 1/2-NR3XLP: 1/2 Inch version
  • 1-NR3XLP: 1 Inch version
  • 114-NR3XLP: 1 1/4 Inch version
  • 112-NR3XLP: 1 1/2 Inch version
  • 2-NR3XLP: 2 Inch version

 

Materials:

  • Main valve body: Low Lead Cast Bronze ASTM B 584
  • Bell housing: UV resistant polymer composite
  • Internals: Stainless steel, 300 Series
  • Stem: Low Lead Brass
  • Elastomers: EPDM (FDA approved)
  • Elastomers: Buna nitrile (FDA approved)
  • Cartridge: Delrin™
  • Springs: 302 Stainless Steel
  • Strainer screen: 300 Series Stainless Steel

 

Typical Installation:

The Wilkins 34-NR3XLP may be installed in any position on potable water lines. Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted in accordance with the latest edition of the Uniform Plumbing Code. The assembly shall be installed with sufficient side clearance for testing and maintenance. Multiple installations are recommended for wide demand variations or where the desired pressure reduction is more than 4 to 1. Suitable for residential and commercial water systems including outdoor installation, below-ground pit installation, and integration with water meters, backflow preventers, expansion tanks, and water heaters.

 

Standards Compliance:

ASSE Listed 1003; IAPMO Listed; CSA Certified; NSF/ANSI/CAN 61; NSF/ANSI/CAN 372 (Lead-Free - 0.25% max. weighted average lead content)

 

Features & Benefits:

  • Integrated 3-in-1 Design: Combines pressure reducing valve, integral by-pass check valve, and strainer in one compact unit, eliminating the need for multiple separate components and saving installation space.
  • Thermal Expansion Protection: Direct acting integral by-pass design prevents buildup of excessive system pressure caused by thermal expansion, protecting plumbing fixtures and water heaters.
  • Easy Maintenance Access: Balance piston design and accessible cartridge allow for servicing without removing the device from the line, reducing downtime and maintenance costs.
  • Lead-Free Compliance: Certified to NSF/ANSI/CAN 61 & 372 with low lead cast bronze construction, meeting strict requirements for potable water applications including residential and commercial installations.

 

FAQ

 

Q: What is the factory preset pressure for the Zurn 34-NR3XLP and can it be adjusted?

A: The Zurn 34-NR3XLP comes factory preset at 50 psi with an adjustable reduced pressure range of 15 to 75 psi. Anytime the valve is adjusted, a pressure gauge must be used downstream to verify the correct pressure setting. Do not bottom the adjustment bolt on the bell housing.

Q: Can the Wilkins 34-NR3XLP be installed in any orientation?

A: Yes, the Model NR3XL may be installed in any position. However, sufficient side clearance must be provided for testing and maintenance access, and local plumbing codes must be followed.

Q: When should multiple pressure reducing valves be installed instead of a single unit?

A: Multiple installations are recommended for applications with wide demand variations or where the desired pressure reduction ratio is more than 4 to 1 (for example, reducing 200 psi inlet pressure to 50 psi outlet pressure).

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.

"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us

OUR HAPPY CUSTOMERS

Go to Table of Content