Buying more than 2? Email us for a discount: support@bottlefillingstations.com

FREE SHIPPING

All Products. No Minimums. 

Elkay  |  SKU: 2-975XL3N

Wilkins 2-975XL3N | Reduced Pressure Principle Backflow Preventer, N-Pattern

Regular price $ 2,293.99

Shipping

🚚✨ Free Shipping in the Continental U.S. 
All Products. No Minimums.


Estimated Shipping Times:


Important Note on Delivery Times

All shipping estimates provided are approximate only. While we always strive to meet or exceed your delivery expectations, we cannot guarantee the exact delivery times listed.

For time-sensitive orders, please contact us directly so we can provide a more accurate lead time estimate based on your specific requirements.

Same Day Shipping

All in stock orders received before 3PM EST will ship the same day. Orders received after 3PM EST will ship the following business day. 

Water Filters, Hand Dryers, & Indoor Bottle Fillers are our most popular in stock items. 

Outdoor Tubular Drinking Fountains

Evergreen normally ships in 5-15 days. Black, Gray and Blue ship in 2-4 weeks. 

Ice Machines

In stock units ship within 48 hours. Other units normally ship in 2-4 weeks.

Other

Orders that ship directly from a manufacturer normally have a firm shipping estimate but those dates are subject to change due to manufacturer production, inventory or shipping. We do our best to estimate ship dates but orders shipping directly from the manufacturer can have unexpected delays. We will confirm tracking information when orders ship directly from a manufacturer but may not have updates or estimates beyond the original estimate. Once your order is placed with the manufacturer, it may not be able to be cancelled even if it hasn't shipped yet.  

Please contact support@bottlefillingstations.com to confirm delivery time for a specific product or quantity. Or to inquire about an existing order. 


Special Case Shipping Rates

 

Please note that shipping rates are subject to change at any time.  We reserve the right to charge an additional fee in addition to the regularly advertised shipping fee for shipping to remote areas not easily accessible by typical freight carrier means (i.e. islands only accessible by ferry). If your order falls into this category, you will be notified upon receipt of your order, and have the option to complete the purchase with additional fee or to cancel the order.  Please note, these instances are very rare, as most locations are reachable by regular freight. If you have any questions, please contact us! 


Key Terms & Conditions

 

Exceptions may apply to islands and other remote territories.

All orders shipped by the carrier of our choice.  

 

 

 


 

 

 

The Wilkins 2-975XL3N protects potable water lines from backsiphonage and backpressure with vertical up/down flow design.

 

Key Specifications:

Size 2 Inches
Maximum Working Pressure 175 PSI
Maximum Working Temperature 180°F
Notable Certifications ASSE 1013; NSF/ANSI/CAN 61 & 372
Connection Type Threaded FNPT End Connections

 

Other Related Variants:

  • 112-975XL3N: 1 1/2 Inches version
  • 1-975XL3N: 1 Inches version
  • 34-975XL3N: 3/4 Inches version

 

Materials:

  • Access Cover(s): Low Lead Cast Bronze ASTM B584
  • Ball Valve Handles: Stainless Steel
  • Elastomers: Buna Nitrile (FDA approved), EPDM (FDA approved), Silicone (FDA approved)
  • Fasteners: 300 series Stainless Steel
  • Main Valve Body: Low Lead Cast Bronze ASTM B584
  • Polymers: NORYL™
  • Spring(s): 300 series Stainless Steel

 

Typical Installation:

Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.

 

Standards Compliance:

ASSE Listed 1013; AWWA Compliant C511; CSA Certified B64.4; cUPC Listed; NSF/ANSI/CAN 61 & 372

 

Features & Benefits:

  • Lead-Free Construction: Meets low-lead requirements for safe potable water applications.
  • Vertical Flow Design: Zurn 2-975XL3N supports both vertical up and vertical down flow installations.
  • Accessible Maintenance: Checks share a single access cover with top-accessible test cocks for easy servicing.
  • Durable Materials: Bronze body and stainless steel components ensure long-term reliability.

 

FAQ

 

Q: What is the Wilkins 2-975XL3N used for?

A: It is a reduced pressure principle backflow preventer designed to protect potable water lines from backsiphonage and backpressure contamination.

Q: Can the Zurn 2-975XL3N be installed for vertical flow?

A: Yes, this N-Pattern model is specifically designed for applications requiring vertical flow up and vertical flow down installation.

Q: What certifications does this backflow preventer meet?

A: It is ASSE Listed 1013, AWWA Compliant C511, CSA Certified B64.4, cUPC Listed, and meets NSF/ANSI/CAN 61 & 372 requirements.

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.

"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us

OUR HAPPY CUSTOMERS

Go to Table of Content