Wilkins 2-975XL2TCUFT | 2" Backflow Preventer, Test Cocks Up
Wilkins 2-975XL2TCUFT | 2" Backflow Preventer, Test Cocks Up is backordered and will ship as soon as it is back in stock.
Shipping
Shipping
🚚✨ Free Shipping in the Continental U.S.
All Products. No Minimums.
Estimated Shipping Times:
Important Note on Delivery Times
All shipping estimates provided are approximate only. While we always strive to meet or exceed your delivery expectations, we cannot guarantee the exact delivery times listed.
For time-sensitive orders, please contact us directly so we can provide a more accurate lead time estimate based on your specific requirements.
Same Day Shipping
All in stock orders received before 3PM EST will ship the same day. Orders received after 3PM EST will ship the following business day.
Water Filters, Hand Dryers, & Indoor Bottle Fillers are our most popular in stock items.
Outdoor Tubular Drinking Fountains
Evergreen normally ships in 5-15 days. Black, Gray and Blue ship in 2-4 weeks.
Ice Machines
In stock units ship within 48 hours. Other units normally ship in 2-4 weeks.
Other
Orders that ship directly from a manufacturer normally have a firm shipping estimate but those dates are subject to change due to manufacturer production, inventory or shipping. We do our best to estimate ship dates but orders shipping directly from the manufacturer can have unexpected delays. We will confirm tracking information when orders ship directly from a manufacturer but may not have updates or estimates beyond the original estimate. Once your order is placed with the manufacturer, it may not be able to be cancelled even if it hasn't shipped yet.
Please contact support@bottlefillingstations.com to confirm delivery time for a specific product or quantity. Or to inquire about an existing order.
Special Case Shipping Rates
Please note that shipping rates are subject to change at any time. We reserve the right to charge an additional fee in addition to the regularly advertised shipping fee for shipping to remote areas not easily accessible by typical freight carrier means (i.e. islands only accessible by ferry). If your order falls into this category, you will be notified upon receipt of your order, and have the option to complete the purchase with additional fee or to cancel the order. Please note, these instances are very rare, as most locations are reachable by regular freight. If you have any questions, please contact us!
Key Terms & Conditions
Exceptions may apply to islands and other remote territories.
All orders shipped by the carrier of our choice.
The Wilkins 2-975XL2TCUFT is a Reduced Pressure Principle Assembly designed to protect potable water lines from both backsiphonage and backpressure contamination where health hazards exist.
Key Specifications:
- Size: 2 Inches
- Maximum Working Water Pressure: 175 PSI
- Maximum Working Water Temperature: 180°F
- Notable Certifications: ASSE 1013, cUPC, CSA B64.4
- End Connections: Threaded ANSI B1.20.1
Other Related Variants:
- 112-975XL2TCUFT: 1 1/2 Inches version
- 1-975XL2TCUFT: 1 Inches version
- 34-975XL2TCUFT: 3/4 Inches version
Materials:
- Body: Low Lead Cast Bronze ASTM B584
- Access Covers: Low Lead Cast Bronze ASTM B584
- Fasteners: 300 Series Stainless Steel
- Elastomers: Silicone and Buna Nitrile
- Polymers: Noryl™
- Springs: 300 Series Stainless Steel
- Ball Valve Handles: Stainless Steel
Typical Installation:
Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. For indoor installations, an air gap fitting is required.
Standards Compliance:
ASSE Listed 1013; cUPC Listed; CSA Certified B64.4; AWWA Compliant C511; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; Meets NSF/ANSI/CAN 61 & 372; UL Classified; C-UL Classified
Features & Benefits:
- Health Hazard Protection: Provides protection against both backsiphonage and backpressure of contaminated water into potable water supply where potential health hazards exist.
- Lead-Free Construction: Meets NSF/ANSI/CAN 61 and 372 standards with less than 0.25% weighted average lead content for safe drinking water applications.
- Full Port Ball Valves: Features full port QT ball valves for maximum flow capacity and easy shut-off operation during testing and maintenance.
- Test Cocks Up Configuration: The Zurn 2-975XL2TCUFT includes test cocks up with integral male 45° flare SAE test fitting for convenient testing and maintenance access.
FAQ
Q: What is the required installation height for the Zurn 2-975XL2TCUFT?
A: The assembly must be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance.
Q: Can this backflow preventer be installed outdoors?
A: Yes, the unit can be installed outdoors with a protective enclosure. However, for indoor installations, an air gap fitting is required and must be provided by others.
Q: What is the maximum working pressure and temperature for this assembly?
A: The maximum working water pressure is 175 PSI and the maximum working water temperature is 180°F, with a hydrostatic test pressure rating of 350 PSI.
NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.