Wilkins 2-950XLTDABFSS | Double Check Detector Backflow Assembly, 2 Inches
Wilkins 2-950XLTDABFSS | Double Check Detector Backflow Assembly, 2 Inches is backordered and will ship as soon as it is back in stock.
Shipping
Shipping
🚚✨ Free Shipping in the Continental U.S.
All Products. No Minimums.
Estimated Shipping Times:
Important Note on Delivery Times
All shipping estimates provided are approximate only. While we always strive to meet or exceed your delivery expectations, we cannot guarantee the exact delivery times listed.
For time-sensitive orders, please contact us directly so we can provide a more accurate lead time estimate based on your specific requirements.
Same Day Shipping
All in stock orders received before 3PM EST will ship the same day. Orders received after 3PM EST will ship the following business day.
Water Filters, Hand Dryers, & Indoor Bottle Fillers are our most popular in stock items.
Outdoor Tubular Drinking Fountains
Evergreen normally ships in 5-15 days. Black, Gray and Blue ship in 2-4 weeks.
Ice Machines
In stock units ship within 48 hours. Other units normally ship in 2-4 weeks.
Other
Orders that ship directly from a manufacturer normally have a firm shipping estimate but those dates are subject to change due to manufacturer production, inventory or shipping. We do our best to estimate ship dates but orders shipping directly from the manufacturer can have unexpected delays. We will confirm tracking information when orders ship directly from a manufacturer but may not have updates or estimates beyond the original estimate. Once your order is placed with the manufacturer, it may not be able to be cancelled even if it hasn't shipped yet.
Please contact support@bottlefillingstations.com to confirm delivery time for a specific product or quantity. Or to inquire about an existing order.
Special Case Shipping Rates
Please note that shipping rates are subject to change at any time. We reserve the right to charge an additional fee in addition to the regularly advertised shipping fee for shipping to remote areas not easily accessible by typical freight carrier means (i.e. islands only accessible by ferry). If your order falls into this category, you will be notified upon receipt of your order, and have the option to complete the purchase with additional fee or to cancel the order. Please note, these instances are very rare, as most locations are reachable by regular freight. If you have any questions, please contact us!
Key Terms & Conditions
Exceptions may apply to islands and other remote territories.
All orders shipped by the carrier of our choice.
NOTICE: Product images may vary from the actual item due to differences in size or configuration options.
The Wilkins 2-950XLTDABFSS is a Double Check Detector Backflow Preventer Assembly designed to protect potable water in fire sprinkler systems from backsiphonage and backpressure.
Key Specifications:
- Size: 2 Inches
- Maximum Working Water Pressure: 175 PSI
- Maximum Working Water Temperature: 180°F
- Notable Certifications: ASSE 1048, UL, C-UL Classified
- End Connections: FNPT, ANSI B1.20.1
Other Related Variants:
- 2-950XLTDABFSSLM: Less meter version
Materials:
- Main valve body: Cast Bronze ASTM B 584
- Access covers: Cast Bronze ASTM B 584
- Fasteners: Stainless Steel, 300 Series
- Elastomers: Silicone (FDA approved)
- Elastomers: Buna Nitrile (FDA approved)
- Polymers: Noryl™, NSF Listed
- Springs: Stainless Steel, 300 series
- Test cock cover: Plastic
Typical Installation:
Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 Inches and a maximum of 30 Inches above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Suitable for horizontal or vertical orientation.
Standards Compliance:
ASSE Listed 1048; UL Classified (horizontal & vertical); C-UL Classified (horizontal & vertical); AWWA Compliant C510; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; NSF/ANSI/CAN 61 & 372 (lead-free)
Features & Benefits:
- Dual Protection: Protects potable water from both backsiphonage and backpressure of polluted water in fire sprinkler systems.
- Leak Detection: Incorporates metered bypass to detect leaks and unauthorized water use for enhanced system monitoring.
- Supervisory Monitoring: Butterfly valve supervisory switches (SS option) provide remote indication of valve position and circuit status for fire alarm systems, UL and FM approved for indoor and outdoor use.
- Easy Maintenance: First and second check valves located at 45° angle and accessible from the top without removing device from line; test cock plugs protect ports from debris.
FAQ
Q: Can the Zurn 2-950XLTDABFSS be installed in both horizontal and vertical orientations?
A: Yes, the Zurn 2-950XLTDABFSS is approved for both horizontal and vertical installation per ASSE 1048, UL, and C-UL classifications.
Q: What is the purpose of the butterfly valve supervisory switches on this model?
A: The SS suffix indicates butterfly valve supervisory switches that are UL and FM approved, providing remote indication of valve position and circuit status for integration with fire alarm systems.
Q: Where should the Wilkins 2-950XLTDABFSS be installed?
A: Install on potable water connections in fire sprinkler systems where low health hazard backflow protection with supervisory monitoring is required, mounted 12 to 30 Inches above adequate drains.
NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.