Zurn Wilkins  |  SKU: 112-975XL2TCUFT

Wilkins 112-975XL2TCUFT | 1 1/2" Reduced Pressure Backflow Assembly

Regular price $ 2,099.99

Shipping

🚚✨ Free Shipping in the Continental U.S. 
All Products. No Minimums.


Estimated Shipping Times:


Important Note on Delivery Times

All shipping estimates provided are approximate only. While we always strive to meet or exceed your delivery expectations, we cannot guarantee the exact delivery times listed.

For time-sensitive orders, please contact us directly so we can provide a more accurate lead time estimate based on your specific requirements.

Same Day Shipping

All in stock orders received before 3PM EST will ship the same day. Orders received after 3PM EST will ship the following business day. 

Water Filters, Hand Dryers, & Indoor Bottle Fillers are our most popular in stock items. 

Outdoor Tubular Drinking Fountains

Evergreen normally ships in 5-15 days. Black, Gray and Blue ship in 2-4 weeks. 

Ice Machines

In stock units ship within 48 hours. Other units normally ship in 2-4 weeks.

Other

Orders that ship directly from a manufacturer normally have a firm shipping estimate but those dates are subject to change due to manufacturer production, inventory or shipping. We do our best to estimate ship dates but orders shipping directly from the manufacturer can have unexpected delays. We will confirm tracking information when orders ship directly from a manufacturer but may not have updates or estimates beyond the original estimate. Once your order is placed with the manufacturer, it may not be able to be cancelled even if it hasn't shipped yet.  

Please contact support@bottlefillingstations.com to confirm delivery time for a specific product or quantity. Or to inquire about an existing order. 


Special Case Shipping Rates

 

Please note that shipping rates are subject to change at any time.  We reserve the right to charge an additional fee in addition to the regularly advertised shipping fee for shipping to remote areas not easily accessible by typical freight carrier means (i.e. islands only accessible by ferry). If your order falls into this category, you will be notified upon receipt of your order, and have the option to complete the purchase with additional fee or to cancel the order.  Please note, these instances are very rare, as most locations are reachable by regular freight. If you have any questions, please contact us! 


Key Terms & Conditions

 

Exceptions may apply to islands and other remote territories.

All orders shipped by the carrier of our choice.  

 

 

 


 

 

 

The Wilkins 112-975XL2TCUFT is a reduced pressure principle backflow prevention assembly designed to protect potable water lines against backsiphonage and backpressure where a health hazard exists.

 

Key Specifications:

  • Size: 1 1/2 Inches
  • Maximum Working Water Pressure: 175 PSI
  • Maximum Working Water Temperature: 180°F
  • Notable Certifications: ASSE 1013, cUPC, CSA B64.4
  • End Connections: Threaded ANSI B1.20.1

 

Other Related Variants:

  • 1-975XL2TCUFT: 1 Inch model size
  • 2-975XL2TCUFT: 2 Inches model size
  • 34-975XL2TCUFT: 3/4 Inches model size

 

Materials:

  • Main Valve Body: Low Lead Cast Bronze ASTM B584
  • Access Covers: Low Lead Cast Bronze ASTM B584
  • Fasteners: Stainless Steel, 300 Series
  • Elastomers: Silicone and Buna Nitrile
  • Polymers: Noryl™
  • Springs: Stainless Steel, 300 Series
  • Ball Valve Handles: Stainless Steel

 

Typical Installation:

Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. For indoor installations, an air gap fitting is required.

 

Standards Compliance:

ASSE Listed 1013; cUPC Listed; CSA Certified B64.4; AWWA Compliant C511; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; Meets NSF/ANSI/CAN 61 & 372; UL Classified; C-UL Classified

 

Features & Benefits:

  • Health Hazard Protection: The Zurn 112-975XL2TCUFT provides protection against both backsiphonage and backpressure of contaminated water into potable water supply where potential health hazards exist.
  • Lead-Free Construction: Built with low lead cast bronze meeting NSF/ANSI/CAN 372 standards with less than 0.25% weighted average lead content for safe drinking water applications.
  • Full Port Ball Valves: The Wilkins 112-975XL2TCUFT includes full port QT ball valves with test cocks up configuration and integral male 45° flare SAE test fitting for convenient testing and maintenance.
  • Durable Materials: Features 300 series stainless steel fasteners and springs, silicone and Buna Nitrile elastomers, and Noryl polymers ensuring long-lasting performance and reliability.

 

FAQ

 

Q: What is the required installation height for the Zurn 112-975XL2TCUFT backflow preventer?

A: The assembly must be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. The installation must ensure no part of the unit can be submerged.

Q: Is an air gap fitting required for this backflow preventer?

A: Yes, for indoor installations, an air gap fitting (Model AG) is required. The air gap adapter is necessary to comply with installation requirements for indoor applications.

Q: What certifications does the 112-975XL2TCUFT meet?

A: The assembly is ASSE Listed 1013, cUPC Listed, CSA Certified B64.4, AWWA Compliant C511, UL and C-UL Classified, and meets NSF/ANSI/CAN 61 and 372 standards for lead-free applications.

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.