Wilkins 112-600XL | Water Pressure Reducing Valve with Integral By-pass & Strainer
Wilkins 112-600XL | Water Pressure Reducing Valve with Integral By-pass & Strainer is backordered and will ship as soon as it is back in stock.
Shipping
Shipping
🚚✨ Free Shipping in the Continental U.S.
All Products. No Minimums.
Estimated Shipping Times:
Important Note on Delivery Times
All shipping estimates provided are approximate only. While we always strive to meet or exceed your delivery expectations, we cannot guarantee the exact delivery times listed.
For time-sensitive orders, please contact us directly so we can provide a more accurate lead time estimate based on your specific requirements.
Same Day Shipping
All in stock orders received before 3PM EST will ship the same day. Orders received after 3PM EST will ship the following business day.
Water Filters, Hand Dryers, & Indoor Bottle Fillers are our most popular in stock items.
Outdoor Tubular Drinking Fountains
Evergreen normally ships in 5-15 days. Black, Gray and Blue ship in 2-4 weeks.
Ice Machines
In stock units ship within 48 hours. Other units normally ship in 2-4 weeks.
Other
Orders that ship directly from a manufacturer normally have a firm shipping estimate but those dates are subject to change due to manufacturer production, inventory or shipping. We do our best to estimate ship dates but orders shipping directly from the manufacturer can have unexpected delays. We will confirm tracking information when orders ship directly from a manufacturer but may not have updates or estimates beyond the original estimate. Once your order is placed with the manufacturer, it may not be able to be cancelled even if it hasn't shipped yet.
Please contact support@bottlefillingstations.com to confirm delivery time for a specific product or quantity. Or to inquire about an existing order.
Special Case Shipping Rates
Please note that shipping rates are subject to change at any time. We reserve the right to charge an additional fee in addition to the regularly advertised shipping fee for shipping to remote areas not easily accessible by typical freight carrier means (i.e. islands only accessible by ferry). If your order falls into this category, you will be notified upon receipt of your order, and have the option to complete the purchase with additional fee or to cancel the order. Please note, these instances are very rare, as most locations are reachable by regular freight. If you have any questions, please contact us!
Key Terms & Conditions
Exceptions may apply to islands and other remote territories.
All orders shipped by the carrier of our choice.
The Wilkins 112-600XL is a water pressure reducing valve with integral by-pass check valve and strainer, designed for residential and commercial potable water systems requiring reliable pressure control and sediment protection.
Key Specifications:
- Size: 1 1/2 Inches
- Maximum Working Water Pressure: 300 psi
- Maximum Working Water Temperature: 140°F
- Notable Certifications: ASSE 1003, IAPMO, CSA
- Connection Type: Single Union
Other Related Variants:
- 12-600XL: 1/2 Inch version
- 34-600XL: 3/4 Inch version
- 1-600XL: 1 Inch version
- 114-600XL: 1 1/4 Inch version
- 2-600XL: 2 Inch version
Materials:
- Low Lead Cast Bronze Body (ASTM B 584)
- Low Lead Brass Components
- Stainless Steel Fasteners (300 Series)
- Low Lead Bronze/Brass Stem & Plunger
- Buna Nitrile Elastomers (FDA Approved)
- EPDM Elastomers (FDA Approved)
- Stainless Steel Seat & Strainer Screen (300 Series)
- Natural Vulcanized Fibre Cap Gaskets
- Acetal (Delrin™) Cap Gaskets
Typical Installation:
Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted in accordance with the latest edition of the Uniform Plumbing Code. The Zurn 112-600XL may be installed in any position. If installed in a pit, vault or inside application, specify the "SC" sealed cage option. Multiple installations are recommended for wide demand variations or where the desired pressure reduction is more than 4 to 1. Anytime a reducing valve is adjusted, a pressure gauge must be used downstream to verify correct pressure setting. Do not bottom adjustment bolt on bell housing.
Standards Compliance:
ASSE Listed 1003; IAPMO Listed; CSA Certified; City of Los Angeles Approved; NSF/ANSI/CAN 61
Features & Benefits:
- Integrated Thermal Expansion Protection: The integral by-pass check valve design prevents buildup of excessive system pressure caused by thermal expansion, protecting plumbing systems and appliances.
- Balanced Piston Design: Enables smooth and responsive reaction to changes in system flow demand while providing protection from inlet pressure changes for consistent outlet pressure.
- Built-in Sediment Protection: Integral 20 mesh strainer screen with separate access cover allows for easy cleaning and maintenance, making the Zurn 112-600XL ideal for systems with sediment and debris concerns.
- Versatile Installation Options: Can be installed in any position and offers multiple configuration options including sealed cage for pit/vault installations and various connection types to meet specific application needs.
FAQ
Q: What is the factory preset pressure setting for the Wilkins 112-600XL?
A: The valve comes factory preset at 50 psi, with an adjustable pressure range of 25 psi to 75 psi for the standard model.
Q: Can this valve be installed vertically or in a pit application?
A: Yes, the 112-600XL may be installed in any position. For pit, vault, or inside applications, specify the "SC" sealed cage option for proper protection.
Q: What maintenance access does this valve provide?
A: The valve features separate threaded access covers for both the plunger and strainer screen, allowing for easy maintenance and cleaning without removing the valve from the line. Provide adequate side clearance for maintenance access during installation.
NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.