Wilkins 1-375XL | Reduced Pressure Principle Backflow Preventer
Wilkins 1-375XL | Reduced Pressure Principle Backflow Preventer is backordered and will ship as soon as it is back in stock.
Shipping
Shipping
🚚✨ Free Shipping in the Continental U.S.
All Products. No Minimums.
Estimated Shipping Times:
Important Note on Delivery Times
All shipping estimates provided are approximate only. While we always strive to meet or exceed your delivery expectations, we cannot guarantee the exact delivery times listed.
For time-sensitive orders, please contact us directly so we can provide a more accurate lead time estimate based on your specific requirements.
Same Day Shipping
All in stock orders received before 3PM EST will ship the same day. Orders received after 3PM EST will ship the following business day.
Water Filters, Hand Dryers, & Indoor Bottle Fillers are our most popular in stock items.
Outdoor Tubular Drinking Fountains
Evergreen normally ships in 5-15 days. Black, Gray and Blue ship in 2-4 weeks.
Ice Machines
In stock units ship within 48 hours. Other units normally ship in 2-4 weeks.
Other
Orders that ship directly from a manufacturer normally have a firm shipping estimate but those dates are subject to change due to manufacturer production, inventory or shipping. We do our best to estimate ship dates but orders shipping directly from the manufacturer can have unexpected delays. We will confirm tracking information when orders ship directly from a manufacturer but may not have updates or estimates beyond the original estimate. Once your order is placed with the manufacturer, it may not be able to be cancelled even if it hasn't shipped yet.
Please contact support@bottlefillingstations.com to confirm delivery time for a specific product or quantity. Or to inquire about an existing order.
Special Case Shipping Rates
Please note that shipping rates are subject to change at any time. We reserve the right to charge an additional fee in addition to the regularly advertised shipping fee for shipping to remote areas not easily accessible by typical freight carrier means (i.e. islands only accessible by ferry). If your order falls into this category, you will be notified upon receipt of your order, and have the option to complete the purchase with additional fee or to cancel the order. Please note, these instances are very rare, as most locations are reachable by regular freight. If you have any questions, please contact us!
Key Terms & Conditions
Exceptions may apply to islands and other remote territories.
All orders shipped by the carrier of our choice.
The Wilkins 1-375XL is a reduced pressure principle assembly designed for potable water protection against backsiphonage and backpressure contamination.
Key Specifications:
- Size: 1 Inches
- Maximum Working Pressure: 175 PSI
- Maximum Working Temperature: 180°F
- Notable Certifications: ASSE 1013, CSA B64.4
- End Connections: Threaded FNPT ANSI B1.20.1
Other Related Variants:
- 112-375XL: 1 1/2 Inches version
- 114-375XL: 1 1/4 Inches version
- 12-375XL: 1/2 Inches version
- 2-375XL: 2 Inches version
- 34-375XL: 3/4 Inches version
Materials:
- Reinforced Nylon Housing (FDA approved)
- Stainless Steel Fasteners (300 Series)
- Silicone Elastomers (FDA Approved)
- Buna Nitrile Elastomers (FDA Approved)
- Delrin Internals
- Nylon Internals
- Stainless Steel Springs (300 series)
- Low Lead Cast Bronze Ball Valves (ASTM B 584)
- Stainless Steel Struts (300 Series)
Typical Installation:
Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches (305mm) and a maximum of 30 inches (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.
Standards Compliance:
ASSE Listed 1013; cUPC Listed; CSA Certified B64.4; AWWA compliant C511; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; NSF/ANSI/CAN 61 and 372
Features & Benefits:
- Dual Protection: Provides comprehensive protection against both backsiphonage and backpressure contamination in potable water systems.
- Lead-Free Construction: Meets NSF/ANSI/CAN 372 requirements with less than 0.25% weighted average lead content for safe drinking water applications.
- Durable Materials: Features reinforced nylon housing with FDA-approved elastomers and stainless steel components for long-lasting performance.
- Versatile Installation: Suitable for indoor or outdoor installation with optional air gap and strainer configurations available.
FAQ
Q: What is the difference between the Zurn 1-375XL and standard backflow preventers?
A: The Zurn 1-375XL features a lead-free reinforced nylon body that meets NSF/ANSI/CAN 372 standards, making it ideal for potable water applications where health hazards exist. It provides protection against both backsiphonage and backpressure.
Q: What are the installation height requirements for the Wilkins 1-375XL?
A: The assembly must be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains, with sufficient side clearance for testing and maintenance. No part of the unit can be submerged.
Q: Can this backflow preventer be used outdoors?
A: Yes, the Wilkins 1-375XL can be installed outdoors with a protective enclosure. For indoor installations, an air gap adapter is required. The unit is rated for temperatures up to 180°F and pressure up to 175 PSI.
NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.
"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us
Always consult with a licensed professional and check local codes before installation. For further details, check the Owners Manual.
Contact us at support@bottlefillingstations.com with any questions.