Zurn ZTR6203-ULF Installation Guide

The Zurn ZTR6203‑ULF EcoVantage® Exposed Sensor Piston Flush Valve is engineered for ultra‑low‑flow urinals. Delivering 0.125 gpf performance, it combines water efficiency with reliable piston operation in a vandal‑resistant chrome finish.


Key Installation Requirements:


  • Exposed, sensor‑operated piston valve for urinals
  • Flush volume: 0.125 gpf (WaterSense labeled)
  • Supply line pressure: 25–80 PSI
  • Power options: Hardwired (7.6 VDC input) or battery pack
  • Top spud connection with spud coupling and flange included

Important Notes Before Installing:


  • Always depressurize water line before servicing
  • Ensure sensor lens is unobstructed for accurate activation
  • Do not install in areas subject to freezing temperatures without protection
  • Use chloramine‑resistant seals and filtered bypass piston for long‑term reliability
  • Secure valve firmly to resist vandalism and maintain alignment

Basic Installation Overview:


  1. Shut off water supply and depressurize line
  2. Install spud coupling and flange onto urinal top spud
  3. Mount valve body and secure with adjustable tailpiece
  4. Connect supply line and tighten union nut
  5. Wire hardwired power or install battery pack
  6. Pressurize system slowly and check for leaks
  7. Test sensor activation and manual override button
  8. Adjust piston and regulator if needed for proper flush volume