The Oasis PG8EBF is a wall-mounted refrigerated fountain with a contactless bottle filler, delivering 8.0 GPH of chilled water to both the fountain and the filler.


Before You Begin

  • Tools: Power drill with pilot bit, T15 Torx driver, #2 Phillips and slotted screwdrivers, 1/4" nut driver, bubble level, and tape measure.
  • Not included: Wall anchors and fasteners for the hanger bracket, unit, and bottle filler frame, a 1-1/4" P-trap, and a water shut-off valve.
  • Plumbing: Provide a 3/8" water supply stub-out and a 1-1/4" IPS drain stub-out. Maximum supply pressure is 100 PSI. Use a regulator if pressure spikes could exceed it.
  • Electrical and ventilation: The cooler and the bottle filler each have a power cord, so you need two outlets or a splitter, on a 20A minimum GFCI device. Allow 4" of clearance per side for ventilation.
  • Codes and reference: Some states require a licensed plumber. Check local codes for mounting height, and see the installation manual for the rough-in diagram.


Step-by-Step Installation Guide

  1. Hang the cooler: Flush the building water supply line first. Mount the hanger bracket with 2 anchors, making sure it's level, then hang the unit on it. It must rest on the galvanized steel frame, not under the return edge of the stainless steel basin top.
  2. Secure the unit: Remove the front panel (2 front T15 screws at the base and 2 under the fountain nose). Mark the 2 lower anchor locations, take the unit down to drill the pilot holes, then rehang it and fasten it with anchors.
  3. Connect the drain and water: Install a P-trap between the drain stub-out and the basin drainpipe. Connect the supplied copper inlet tube to the shut-off valve, leaving the 1/4" line on the cartridge valve connected. Turn on the water and press the push pads until the stream is steady, then check for leaks.
  4. Mount the bottle filler frame: Center the rubber gasket on top of the cooler against the wall. Set the wall frame on the gasket, mark the holes, and fasten it to the wall, pulling the plastic tubing up through the frame opening.
  5. Connect the bottle filler: Slide the sponge insulation over the water line and connect it to the solenoid valve inlet on the back of the bottle filler. Attach the tether to the cleat on the mounting frame. Feed the power supply terminals and green ground wire through the bushing in the cooler top, connect the terminals, and attach the ground wire to the cooler frame ground. Then set the cabinet into the gasket groove and fasten it with 2 Torx screws.
  6. Power up and test: Spin the condenser fan blade by hand to confirm it's clear, then plug in both power cords. Turn on the water and place a container in the alcove to release trapped air, then check for leaks. Adjust the fountain stream to at least 4" high. Reinstall the front panel and top cap.