Oasis PG8ACSL Installation Guide

The Oasis PG8ACSL is a wall-mounted bi-level electric water cooler with a non-refrigerated fountain, delivering 8.0 GPH of chilled water. It can be installed with the cooler on the right (standard) or the left (alternate).


Before You Begin

  • Tools: Power drill with pilot bit, T15 Torx driver, slotted screwdriver, bubble level, tape measure, and a tool for cutting plastic pipe.
  • Not included: Wall anchors (8 per unit), 1-1/4" P-trap, and a water shut-off valve.
  • Plumbing: Provide a 3/8" water supply stub-out and a 1-1/4" IPS drain stub-out. Maximum supply pressure is 100 PSI. Use a regulator if pressure spikes could exceed it.
  • Electrical and ventilation: A 20A minimum GFCI-protected outlet is required. Allow 4" minimum clearance per side for ventilation.
  • Codes and reference: Some states require a licensed plumber. Check local codes for mounting height, and see the installation manual for rough-in dimensions.


Step-by-Step Installation Guide

  1. Prepare the site: Flush the building water supply line before installing. The cooler must always be on the right side for proper airflow. For a left-side-high layout, follow the alternate rough-in diagram and swap the patch plate and waste drains between units.
  2. Install the hanger brackets: Mount the brackets on the wall with 2 anchors each, making sure both are level, then hang the units on them. Hang each unit on the galvanized steel frame, not under the stainless steel basin's return edge.
  3. Secure the units: Remove the front panels (T15 screws), mark the mounting holes, then take the units down to drill pilot holes. Rehang and fasten with wall anchors.
  4. Connect the drain: Install the included drain components, with the insulation sponge tubing on the brass drain pipe. Connect a P-trap to the drain stub-out and basin drainpipes, cutting the pipe to fit if needed.
  5. Connect the water supply: Attach the copper inlet tube to the shut-off valve and join it to the union fitting. Replace the push-fit plug on the cold tank with the 1/4" union fitting and connect the fountain line to it. Turn on the water and run both bubblers until the stream is steady, checking for leaks.
  6. Adjust, power, and finish: Turn the adjustment knob under the fountain nose until the stream is at least 4" high. Spin the condenser fan by hand to confirm it's clear, then plug in the unit. Reinstall the front panels once everything is working.


Looking for the Oasis PG8ACSL Bi-Level Water Cooler?

Oasis PG8ACSL Bi-Level Water Cooler with Fountain, 8.0 GPH Chilling
Bi-Level Water Cooler w/ Fountain Oasis PG8ACSL Wall-mounted bi-level electric water cooler with fountain and 8.0 GPH chilling. Available in Greystone, Sandstone, or Stainless Steel.
Shop Now