Oasis PFCP10EBF Installation Guide

The Oasis PFCP10EBF is a freestanding refrigerated bottle filler with a contactless sensor and built-in filtration, delivering 10.0 GPH of chilled water for indoor use.


Before You Begin

  • Tools and parts: A T15 Torx driver. The drain pipes, elbows, P-trap, and stabilizer bracket are included. Wall anchors, the 1/4" O.D. supply tube, and the drain elbow coupling are not.
  • Plumbing: Provide a 1/4" O.D. water supply at 45 to 100 PSI and a connection to the building drain for the 1-1/2" O.D. drainpipe.
  • Electrical: A 115V outlet on a 20A minimum GFCI device is required, and the unit must be grounded. Check the data plate to confirm the voltage.
  • Clearance and reference: Allow 4" of clearance at the rear, and at the sides if installed in an alcove or corner. See the installation manual for the dimensional drawing and electronics setup.


Step-by-Step Installation Guide

  1. Unpack the unit: Carefully unpack the filler and remove the front panel by taking out the 2 T15 screws at the bottom. Take out the drainpipes, drain elbows, and P-trap packed inside. The filter is also packed inside the cabinet for shipping.
  2. Assemble and connect the drain: Connect the drainpipes, elbows, and P-trap to the drip tray tailpiece, and feed the 1-1/2" O.D. P-trap through the snap bushing at the back of the cabinet. Attach the drainpipe to an elbow coupling (not included) and connect it to the building drain.
  3. Install the filter: Unpack the filter and remove its sanitary cap. Orient it with the rectangular lug on top facing forward, push it up into the filter housing, and turn it a quarter turn to the right until it stops.
  4. Connect the water supply: Flush the building supply line first. Push the 1/4" O.D. supply tube through the collet of the quick-connect fitting on the back of the unit until it seats firmly at the bottom of the fitting. Cut the tube square, and don't deform it or leave marks on it.
  5. Secure and power the unit: Fasten the stabilizer bracket to the unit with the supplied screws, then anchor it to the wall. Spin the fan blade by hand to confirm it's clear, then plug into the GFCI outlet.
  6. Flush, test, and finish: Place a container in the alcove. Water flow is delayed until the filter fills, then flush until the water runs clear. Check for leaks, then repeat with a bottle 2 or 3 times to purge air until the stream is steady. Reinstall the front panel with its 2 screws.