The Oasis MMRSLEBF is a non-refrigerated, in-wall bi-level fountain with a contactless Aqua Pointe bottle filler, delivering ambient water from both the fountains and the filler.
Before You Begin
- Plumbing: Provide a 3/8" O.D. water supply and a 1-1/2" or 1-1/4" IPS waste stub-out. Maximum supply pressure is 100 PSI. The stop valve, short radius trap, pipe connectors, and 3/8" compression fittings are not included.
- Electrical: A 115V grounded duplex receptacle on a 20A minimum GFCI device is required. Flexible conduit is recommended, and voltage must match the unit's data plate.
- Wall opening: The unit mounts in the recessed frame supplied with it. Prepare the wall opening and rough-in per the manual's roughing-in drawing.
- Codes and reference: Some states require a licensed plumber. See the installation manual for rough-in details and sensor adjustment.
Step-by-Step Installation Guide
- Set the frame: Insert the frame assembly into the wall opening and secure it to the studs. The front flange must sit flush with the finished wall surface.
- Prepare the upper panel: Install the waste tee on the bottle filler tailpiece and attach the fountain mounting plate to the frame. Feed the remote toggle button through the plate, attach the green ground wire, and plug in the sensor cord. Then fasten the upper panel with 2 screws.
- Prepare the fountains: Remove the bottom plates from the fountain arms and save the screws. Snap the reveal gaskets onto the arms and fit compression connectors on the waste tubes, sliding them back out of the way.
- Hang the fountains: Hang the upper fountain first, feeding its waste tube into the waste stub as you go. Then hang the lower one. Tighten both to the mounting plates with the supplied nuts, bolts, and washers.
- Connect the plumbing: Tighten the waste connections, then connect the 3/8" water supply with a compression fitting. Link the upper fountain's inlet with the supplied water tube assembly, then connect the lower fountain's inlet.
- Test and finish: Turn on the water, check for leaks, and run the bubblers until the air is purged and the taste is satisfactory. Adjust the regulator for stream height and test the sensor. Fasten the bottom panels, slide the gaskets into place, and refit the fountain bottom plates.