Elkay VRCTLDDWSK Installation Guide

The Elkay VRCTLDDWSK is a vandal‑resistant bi‑level bottle filling station and fountain. Designed for high‑traffic public areas, it delivers non‑filtered, non‑refrigerated water with heavy‑duty construction and ADA compliance.


Key Installation Requirements:


  • Wall‑mounted installation with in‑wall carrier support
  • Cold water line only (40–100°F operating temperature)
  • Supply line pressure: 20–105 PSI (regulator required if above 105 PSI)
  • Drain connection required for both fountain basins and bottle filler
  • No electrical connection required (mechanical activation)
  • Follow ADA guidelines for installation height and accessibility

Important Notes Before Installing:


  • Do not connect to hot water lines
  • Unit is filterless and non‑refrigerated — delivers ambient water only
  • Always depressurize water line before servicing
  • Outdoor installation requires winterization or protection in extreme climates
  • Ensure proper drainage to avoid water damage from spillage
  • Secure fountain firmly to wall structure to meet vandal‑resistant requirements

Basic Installation Overview:


  1. Mount in‑wall carrier securely to support dual fountain and bottle filler weight
  2. Position fountain and bottle filler assembly, secure to wall structure
  3. Connect cold water supply line to inlet
  4. Connect drain lines from both basins and bottle filler to building drain system
  5. Pressurize system slowly and check for leaks
  6. Test mechanical push‑button activation for proper flow
  7. Install bottom cover plates and finish trim

For complete specifications and installation guidelines, download the official VRCTLDDWSK Spec Sheet and the Installation & Maintenance Manual.