Elkay lzstl8wssp-pf Installation Guide

The Elkay LZSTL8WSSP-PF is an enhanced ezH2O® bi-level bottle filling station with integrated filtration and refrigeration. Designed for schools, offices, healthcare facilities, and other commercial environments, it combines touchless bottle filling, chilled filtered drinking water, and dual ADA-compliant drinking fountains in a durable stainless steel design.


Key Installation Requirements:


  • Wall-mounted installation with appropriate in-wall carrier support
  • Cold water line only (40–100°F operating temperature)
  • Electrical supply: 115V / 60Hz grounded outlet with GFCI protection
  • Drain connections required for both fountain basins and bottle filler
  • Maintain clearance for filter replacement and refrigeration servicing
  • Follow ADA guidelines for installation height and accessibility

Important Notes Before Installing:


  • Do not connect to hot water lines
  • Always depressurize the water line before servicing or replacing the filter
  • Use only genuine Elkay replacement filters to maintain certified filtration performance
  • Ensure sensor activation areas remain unobstructed for reliable bottle filling operation
  • Provide adequate ventilation clearance around refrigeration components
  • Inspect all plumbing and electrical connections before placing the unit into service

Basic Installation Overview:


  1. Install the carrier system securely according to manufacturer specifications
  2. Connect the cold water supply line and flush plumbing thoroughly
  3. Install the filter head and filter cartridge assembly
  4. Connect drain lines from both fountain basins to the building drainage system
  5. Mount the cooler and bottle filler assembly to the carrier
  6. Connect electrical power to a grounded outlet
  7. Pressurize the system and inspect all connections for leaks
  8. Test bottle filler activation, cooling performance, and water flow
  9. Install access panels and complete final adjustments