Buying more than 2? Email us for a discount: support@bottlefillingstations.com

FREE SHIPPING

All Products. No Minimums. 

Elkay EMABFTLDDLC Installation Guide

The Elkay EMABFTLDDLC is a bi‑level drinking fountain designed for durability and accessibility. This filterless unit delivers ambient water service with dual ADA‑compliant access points, making it suitable for schools, offices, and public facilities.


Key Installation Requirements:


  • Wall‑mounted installation with in‑wall carrier support
  • Cold water line only (40–100°F operating temperature)
  • Supply line pressure: 20–105 PSI (regulator required if above 105 PSI)
  • Drain connections required for both fountain basins
  • Follow ADA guidelines for installation height and accessibility

Important Notes Before Installing:


  • Do not connect to hot water lines
  • Unit is filterless — delivers ambient water only
  • Always depressurize water line before servicing
  • Outdoor installation requires winterization or protection in extreme climates
  • Ensure proper drainage to avoid water damage from spillage
  • Secure fountains firmly to wall structure to resist vandalism

Basic Installation Overview:


  1. Install in‑wall carrier to support dual fountain weight
  2. Position fountain assembly and secure to wall structure
  3. Connect cold water supply line to inlet
  4. Connect drain lines from both basins to building drain system
  5. Pressurize system slowly and check for leaks
  6. Test bubbler stream height; adjust regulator if needed
  7. Install cover plates and finish trim

For complete specifications and installation guidelines, download the official EMABFTLDDLC Spec Sheet and the Installation Manual.


Want to Order the EMABFTLDDLC Drinking Fountain or Get a Custom Quote?


Shop EMABFTLDDLC Drinking Fountain


Go to Table of Content