The Elkay AP99 stainless steel access panel installs in an 8" x 8" wall opening to provide access to the water supply and drain connections behind a drinking fountain. Professional installation by a licensed contractor or plumber is strongly recommended to ensure a square opening, proper frame depth, and a secure fit.
Key Installation Requirements:
- Wall opening of 8" x 8" (203 mm x 203 mm)
- Frame face set flush with or a maximum of 7/8" (22 mm) behind the finished wall
- Fasteners to secure the frame through its mounting holes (not included)
- Allen wrench for the (4) hex socket screws (not furnished)
Important Notes Before Installing the AP99:
- Wall fasteners are not included. The installer must supply fasteners to secure the frame to the wall.
- Position the frame with its flanges on the left and right sides of the opening.
- The panel provides access only. Plumbing connections for the water supply and drain are provided by others.
- Elkay doesn’t specify a fixed mounting height. Set the panel height to suit the fountain and application.
- Always refer to the official Elkay AP99 Spec Sheet for dimensions, and to the fountain's own installation manual for unit-specific steps.
Basic Installation Overview:
- Prepare an 8" x 8" (203 mm x 203 mm) wall opening at the height required for the application.
- Position the (4) clips on the frame's flanges with the flat side of the clips toward the front.
- Place the access panel frame into the wall opening with the flanges on the left and right sides, keeping the frame face flush with or a maximum of 7/8" behind the finished wall.
- Secure the frame in place through the mounting holes using fasteners provided by others.
- Place the access panel over the frame and secure it with the (4) #8-32 x 1.50" hex socket screws, tightening them with an Allen wrench.
For complete step-by-step instructions, download the official Elkay AP99 Access Panel Installation Instructions