Buying more than 2? Email us for a discount: support@bottlefillingstations.com

FREE SHIPPING

All Products. No Minimums. 

How to Install the Everpure EV985700 (EF-3000) Drinking Water System

Everpure EV985700 EF-3000 Drinking Water System Installation

The Everpure EV985700 (EF-3000) Drinking Water System is a residential drinking water system that installs under the sink. It suits homeowners who want filtered water from their existing kitchen tap without adding a separate faucet. It reduces chlorine taste and odor, dirt and cloudiness, lead, and cysts such as Cryptosporidium and Giardia

This guide covers first-time installation of the system, which takes an estimated 15–30 minutes. If you already have the system installed and only need to replace the cartridge, see our Everpure EV985750 Filter Replacement Guide.

💧 Shop the EF-3000 System Now

Safety & Preparation

Choose the Mounting Location

The system installs vertically, with the cartridge hanging down. It needs a space of 5" W x 20" H x 5" D, which includes 2-1/2 inches of clear space below the unit for cartridge changes. Leave room above the head to open and close the built-in shut-off handle, and pick a spot that is easy to reach for future cartridge changes.

EF-3000 system dimensions and required cartridge clearance

EF-3000 System Dimensions

🔍 Before you start: confirm the Everpure EF-3000 Drinking Water System suits your supply. It is for cold water use only, at 35–100°F (2–38°C), with a supply pressure of 10–125 psi (0.7–8.6 bar), non-shock.

Have Everything Ready

🧰 Materials

Included with the system:

🔵 QL3 filter head with built-in shut-off
💧 EF-3000 cartridge
🔩 Mounting screws and locking washers
🔧 Elbow fitting
🔗 Two sets of unions (3/8" x 1/2" and 3/8" x 3/8")
🧻 Plumber tape
⏱️ Filter timer

You will also need:

🪛 Phillips screwdriver
🔧 Adjustable wrench
📏 Tape measure
✏️ Pencil
🚰 Braided supply line for the inlet side (see the note below)

⚠️ Safety Precautions

🚫 Do not use on water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system
📋 Check for compliance with state and local plumbing laws and regulations before installing

⚠️ Note: The manual's inlet step calls for a braided supply line that is not on its included-parts list, so confirm you have one before you start.

Step-by-Step Installation

🔧 6 STEPS · ABOUT 15–30 MINUTES
1
Check the Mounting Location & Parts. Measure 20 inches up from the base of the cabinet and mark where the top of the filter head will sit. Confirm the spot meets the space and access requirements, and check your parts against the list in Safety & Preparation.
2
Mount the Filter Head. Wrap plumber tape around the small threads of a union, in the direction of the threads, and screw it into the open end of the elbow. Tape the elbow's threads and screw the elbow into the inlet (left) side of the head. Then tape a second union and screw it into the outlet (right) side. Hand-tighten only. Use the 3/8" x 1/2" unions if your existing braided tubing has 1/2-inch connections, and the 3/8" x 3/8" unions if it does not. Finally, secure the head to the cabinet wall with the supplied screws and washers.
3
Connect the Inlet Supply. Close the cold water shut-off valve under the sink, then open the faucet's cold line to release pressure. Unscrew the existing braided tubing from the top of the shut-off valve. Attach the supply line to the top of the valve and connect its other end to the inlet side of the head, at the elbow and union.
4
Connect the Outlet to the Faucet. Attach the open end of the existing braided tubing to the union on the outlet (right) side of the head. Hand-tighten to avoid damaging the fittings.
5
Install the Cartridge & Check for Leaks. Lift the handle of the built-in shut-off on the head and hold the head firmly with one hand. Align the cartridge lug with the label on the head, push the cartridge upward, and turn it to the right about a quarter turn until rotation stops. Then open the cold water valve and check for leaks up to the inlet elbow.
6
Flush the System & Activate the Timer. Open the faucet, then lower the shut-off handle to send water to the sink and flush the new cartridge. The flush time is in What to Expect After Installation. Activate the filter timer by pinching its bubble until it pops, then peel off the backing and attach it where you can see it.

 💧 Shop the EF-3000 System

Common Installation Mistakes

These are the installation mistakes to avoid, each with its fix. Where another section covers the requirement, the link points back to it:

🚫
Overtightening the Elbow and Unions

These fittings are hand-tightened only, and forcing them with a wrench can damage them. If a connection leaks, recheck the plumber tape rather than adding force. See Step-by-Step Installation and Troubleshooting & FAQ.

⛔
Installing a Cartridge From Another EF Model

The EF-1500 and EF-6000 cartridges are separate parts with different mounting heights, so they are not substitutes. Confirm the part number before installing; the EF-3000 cartridge is the EV985750, covered in When to Replace Your Filter Cartridge.

🧻
Skipping the Plumber Tape

Untaped threads are a common source of small leaks. Disconnect the fitting, wrap the tape in the direction of the threads, and reconnect it by hand, as in Step-by-Step Installation.

🔗
Using the Wrong Union Set

Two union sets are included to fit different tubing connections. Check the connection size on your existing braided tubing and use the matching set, as described in Step-by-Step Installation.

📐
Mounting Out of Position

The head and cartridge must hang vertically with clearance below the cartridge. If the unit is crooked or too close to the cabinet floor, remount it before connecting water. The space requirements are in Safety & Preparation.

🌀
Crimping the Tubing or Blocking the Handle

Tubing that is kinked, or a head with no room above it for the built-in shut-off handle, is a fixable layout problem. Reposition the head or reroute the tubing so the handle moves freely and the line runs without a bend.

↔️
Reversing Inlet and Outlet

Supply goes to the left (elbow) side of the head and the faucet line to the right (union) side. If they are swapped, reconnect them following the inlet and outlet steps in Step-by-Step Installation.

🔄
Stopping Short of the Full Quarter Turn

A cartridge that is not turned until rotation stops is not locked in. Realign the lug with the head label, push the cartridge upward, and turn it again, as in Step-by-Step Installation.

What to Expect After Installation

A new cartridge needs to be flushed at full flow for at least three minutes to purge trapped air and loose carbon, as described in step 6 of Step-by-Step Installation. Water can look cloudy or sputter at first because of air in the filter and tubing. This clears with flushing and use, and cloudiness that lasts more than a week is outside what the manual describes as normal.

Once the flush is done, compare what you see against the two columns below:

✅ Normal After Installation

💨 Cloudy water or sputtering in the first minutes, which clears as the flush runs
🔒 No moisture at the inlet elbow, unions, or cartridge head
🚰 Steady flow at the tap
⏱️ Filter timer activated and placed where you can see it

🔎 Worth a Second Look

💧 Moisture or dripping at the inlet elbow, unions, or cartridge head
🌫️ Cloudy water that lasts more than a week
📉 Flow at the tap that is not steady
⏱️ Filter timer not yet activated

If anything lands in the right-hand column, see Troubleshooting & FAQ. For how the filter timer fits into the replacement schedule, see When to Replace Your Filter Cartridge.

Official Product Resources

The EF-3000 spec sheet lists its ratings and certified reductions, and the EF-Series manual has the parts list, mounting dimensions, and installation sequence. The manual covers the whole EF Series, so use the EF-3000 entries.

When to Replace Your Filter Cartridge

Replace the cartridge as soon as any one of these three limits is reached, whichever comes first:

💧
3,000 Gallons

The cartridge's rated capacity (11,356 L).

🐌
Flow Becomes Too Slow

Replace the cartridge when flow at the tap drops too far.

🗓️
At Least Annually

Replace it at least once a year, even if the other two limits have not been reached.

⏱️ Filter timer: the timer you activated in Step-by-Step Installation works as a visual reminder. When its white window is completely filled with red, it is time to replace the cartridge.

The replacement for this system is the Everpure EV985750, the EF-3000 cartridge. It is sold as a 1-pack and as the EV985756 6-pack. To stay on schedule without tracking dates, the 12-month filter subscription for the EV985750 is a set-it-and-forget-it option, with your annual replacement scheduled automatically.

💧
EV985750 — 1-Pack

Single replacement cartridge

Shop Now
📦
EV985756 — 6-Pack

Keep the next replacements on hand

Shop Now
🔁
Auto-Delivery Subscription

1 cartridge delivered every 12 months

Subscribe

How to Maximize the Lifespan of Your Filter

A few routine habits keep the system running as installed and the cartridge changes on time:

  • Stay within the operating limits — the water temperature and pressure ranges are in Safety & Preparation.
  • Keep the area under the sink clear — so the cartridge and the built-in shut-off stay easy to reach.
  • Check the unions and tubing now and then — look for slow leaks, and recheck any connection that is damp.
  • Keep tubing runs short — the performance data sheet in the manual advises using the minimum length of tubing possible.
  • Record the install date — keep it next to the filter timer so you have two ways to track the schedule.
  • Do not run the cartridge past its limits — the replacement interval is in When to Replace Your Filter Cartridge.

Troubleshooting & FAQ

A connection or the head is leaking — what should I check?

Recheck the plumber tape on the elbow and union threads and make sure the fittings are hand-tightened. Also confirm the cartridge is turned a full quarter turn to the right until rotation stops. The connection steps are in Step-by-Step Installation.

Water flow is low after installation.

Confirm the cold water shut-off valve is fully open and the shut-off handle on the head is lowered. Check that the braided tubing is not crimped.

Why is the water cloudy or sputtering after installation?

Trapped air in the filter and tubing causes early cloudiness and sputtering, and it clears as the new cartridge is flushed and used. Cloudiness lasting more than a week is outside what the manual describes as normal. The flush is covered in What to Expect After Installation.

Does the system need a separate faucet?

No. The system connects to the cold water line of your existing faucet, so no additional faucet is required.

Can I use the system with hot water?

No. It is for cold water use only, within the temperature range listed in the operating limits in Safety & Preparation.

Which replacement cartridge does the system use?

The Everpure EV985750, which is the EF-3000 cartridge. The EF-1500 and EF-6000 use different cartridges. Replacement timing and ordering options are in When to Replace Your Filter Cartridge.

Does the EF-3000 mount differently from the EF-1500 or EF-6000?

Yes. The manual gives a 20-inch mounting height for the EF-3000, compared with 15 inches for the EF-1500 and 22 inches for the EF-6000.

Replacement cartridges for the Everpure EF-3000 Drinking Water System are below, along with a higher-capacity system from the same series:

Everpure EV985750 EF-3000 Replacement Cartridge (1-Pack)

The EF-3000 replacement cartridge, sold as a single unit. Timing is covered in When to Replace Your Filter Cartridge.

View Product →
Everpure EV985756 EF-3000 Replacement Cartridges (6-Pack)

The same cartridge in a 6-pack, so future replacements are on hand.

View Product →
Everpure EV985500 EF-6000 Drinking Water System

A larger-capacity option in the same series, rated for 6,000 gallons at 1.67 gpm and mounted at 22 inches.

View Product →
🔁

Never Run Out of Replacement Cartridges

Subscribe to the EV985750 and a cartridge is delivered automatically every 12 months.

Subscribe

Conclusion

Installing the EF-3000 comes down to a short sequence: mark the mounting height, mount the head, connect the inlet and outlet lines, install the cartridge, and flush the system. Check each connection for leaks as you go, and activate the filter timer once the flush is done.

After that, replace the cartridge on schedule, or let the subscription handle the timing. Keep a spare EV985750 on hand, record each change, and use our Everpure EV985750 Filter Replacement Guide for the procedure.

💧 Shop the EF-3000 System

Leave a comment

Please note: comments must be approved before they are published.

Go to Table of Content