Buying more than 2? Email us for a discount: support@bottlefillingstations.com

FREE SHIPPING

All Products. No Minimums. 

Zurn Wilkins  |  SKU: 1-975XLU

Wilkins 1-975XLU | Reduced Pressure Principle Backflow Preventer, 1 Inches

Regular price $ 929.99

Shipping

🚚✨ Free Shipping in the Continental U.S. 
All Products. No Minimums.


Estimated Shipping Times:


Important Note on Delivery Times

All shipping estimates provided are approximate only. While we always strive to meet or exceed your delivery expectations, we cannot guarantee the exact delivery times listed.

For time-sensitive orders, please contact us directly so we can provide a more accurate lead time estimate based on your specific requirements.

Same Day Shipping

All in stock orders received before 3PM EST will ship the same day. Orders received after 3PM EST will ship the following business day. 

Water Filters, Hand Dryers, & Indoor Bottle Fillers are our most popular in stock items. 

Outdoor Tubular Drinking Fountains

Evergreen normally ships in 5-15 days. Black, Gray and Blue ship in 2-4 weeks. 

Ice Machines

In stock units ship within 48 hours. Other units normally ship in 2-4 weeks.

Other

Orders that ship directly from a manufacturer normally have a firm shipping estimate but those dates are subject to change due to manufacturer production, inventory or shipping. We do our best to estimate ship dates but orders shipping directly from the manufacturer can have unexpected delays. We will confirm tracking information when orders ship directly from a manufacturer but may not have updates or estimates beyond the original estimate. Once your order is placed with the manufacturer, it may not be able to be cancelled even if it hasn't shipped yet.  

Please contact support@bottlefillingstations.com to confirm delivery time for a specific product or quantity. Or to inquire about an existing order. 


Special Case Shipping Rates

 

Please note that shipping rates are subject to change at any time.  We reserve the right to charge an additional fee in addition to the regularly advertised shipping fee for shipping to remote areas not easily accessible by typical freight carrier means (i.e. islands only accessible by ferry). If your order falls into this category, you will be notified upon receipt of your order, and have the option to complete the purchase with additional fee or to cancel the order.  Please note, these instances are very rare, as most locations are reachable by regular freight. If you have any questions, please contact us! 


Key Terms & Conditions

 

Exceptions may apply to islands and other remote territories.

All orders shipped by the carrier of our choice.  

 

 

 


 

 

 

The Wilkins 1-975XLU is a reduced pressure principle backflow preventer engineered for high hazard protection on potable water lines, safeguarding against both backsiphonage and backpressure contamination.

 

Key Specifications:

  • Size: 1 Inches
  • Maximum Working Water Pressure: 175 PSI
  • Maximum Working Water Temperature: 180°F
  • Notable Certifications: ASSE 1013, cUPC, CSA B64.4
  • End Connections: FNPT with union ball valves

 

Other Related Variants:

  • 34-975XLU: 3/4 Inches version

 

Materials:

  • Main Valve Body: Cast Bronze ASTM B 584
  • Access Covers: Cast Bronze ASTM B 584
  • Fasteners: Stainless Steel, 300 Series
  • Elastomers: Silicone and Buna Nitrile
  • Polymers: Noryl™
  • Springs: Stainless Steel, 300 Series

 

Typical Installation:

Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.

 

Standards Compliance:

ASSE Listed 1013; cUPC Listed; UL Classified; C-UL Classified; CSA Certified B64.4; AWWA Compliant C511; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; NYC MEA 425-89-M VOL 3

 

Features & Benefits:

  • High Hazard Protection: Provides comprehensive protection against both backsiphonage and backpressure of contaminated water into potable water supply systems.
  • Union Ball Valve Serviceability: Union ball valves allow easy removal of the assembly body from the line for winterization, testing, and maintenance without disrupting the entire system.
  • Durable Bronze Construction: Cast bronze body and access covers ensure long-lasting performance and corrosion resistance in demanding water service applications.
  • Accessible Check Valves: First and second checks are accessible for maintenance without removing the relief valve or entire device from the line, minimizing downtime.

 

FAQ

 

Q: What applications is the Zurn 1-975XLU suitable for?

A: The Zurn 1-975XLU is designed for installation on potable water service lines where high health hazard protection is required, including commercial and industrial applications requiring protection against contaminated water backflow.

Q: How does the union ball valve configuration benefit maintenance?

A: The union ball valves positioned between the body and shut-offs allow for easy body removal for winterization or maintenance without cutting pipes or disrupting the entire water line.

Q: What is the required installation height for the Wilkins 1-975XLU?

A: The Wilkins 1-975XLU must be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance, and no part of the unit can be submerged.

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.