Refrigerated Surface Bottle Filler Installation

Installation

  • Designed for indoor use only; do not install outdoors or in humid environments.
  • Mount securely to wall using hanger bracket and proper fasteners; add carrier support if wall is insufficient.
  • Connect 3/8" O.D. copper water supply line with installer-supplied shut-off valve.
  • Install 1-1/4" waste outlet pipe and P-trap per local plumbing codes.
  • Provide grounded 115V, 60Hz, 20A dedicated electrical outlet with GFCI protection.
  • If installation is difficult, contact a licensed plumber or authorized Elkay service technician.

Maintenance

  • Inspect water and drain connections periodically for leaks.
  • Replace filter cartridge annually or after 3,000 gallons (LZ filtered units only).
  • Reset filter monitor and bottle count as needed via programming button.
  • Clean sensor lens and basin with non-abrasive cleaner to maintain performance.
  • Verify proper dispensing and LED filter status during routine facility checks.

NOTICE

  • Water supply pressure must be between 20–105 psi (40 psi minimum for filtered units).
  • Do not use piercing-type saddle valves; use dielectric coupling to isolate cooler from building plumbing.