The Pentair 161111 GRO-475B is a 4-stage reverse osmosis system that connects to your cold water supply line, a dedicated drinking water faucet with air gap, and its own 3.2-gallon storage tank. It reduces lead, arsenic, TDS, fluoride, and chlorine taste and odor, producing up to 75 gallons per day.

Before You Begin

  • Tools needed: a hand or electric drill (cordless preferred), two adjustable wrenches, slotted and Phillips screwdrivers, a file, safety glasses, drill bits (1/8", 3/16", 1/4", 3/8"), a tube cutter or utility knife, a pencil, a towel, and a bucket. If your sink doesn't have a hole for a separate faucet, add a center punch, a 3/4" hole saw or drill bit, and a safety mask.
  • Safety first: Install on the cold water line only. Your water supply should be within 40–100 psi, 40–100°F, under 2000 ppm TDS, under 10 gpg hardness, and pH 3–11. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection.
  • Cartridges: The GRO-475B uses FDF1-RC, GRO75-RC, F1B1-RC, and F1GC-RC cartridges, which come pre-installed in the correct sequence.

Step-by-Step Installation Guide

  1. Turn off the cold water supply line (install a shut-off valve first if needed), drain the line, then install the feed adapter valve onto the supply valve and connect the riser to it.
  2. Choose a faucet location and drill a 3/4" hole if needed. Mount the faucet with its drain tubing, chrome plate, and locking nut — making sure the 1/4" red drain line (with its flow restrictor still attached) is securely connected to the system manifold before attaching it to the faucet.
  3. Install the drain clamp on a vertical section of the drainpipe about 6" above the trap, then connect the faucet's drain tubing to it with a straight, kink-free run to prevent reject water from leaking through the air gap.
  4. Mount the system vertically in a solid location under the sink, then connect the blue outlet tubing from the faucet to the system.
  5. Connect the storage tank to the system: wrap the tank threads with plumber's tape, thread on the tank valve, then run blue tubing from the tank valve to the system's quick-connect fitting. Mount the system on the wall and connect the remaining blue tubing from the system to the water supply adapter.
  6. Close the tank valve, turn on the cold water supply, and lift the faucet handle to lock it open, letting it drip for 30 minutes, then fully open the supply and let it drip for 12 more hours. Close the faucet, open the tank valve to fill (about 3 hours), then flush the post-filter by opening the faucet for 4–5 minutes and letting the tank refill — repeat this fill-and-flush cycle 4 times, checking for leaks throughout.

Looking for Pentair GRO-475B RO system? Shop here.