Installation
- Designed to retrofit Oasis and Sunroc coolers and bottle fillers across multiple series (P8AC, Radii, Modular, Fully Recessed, PCP, PLF_FA, P_FA, and on‑wall bottle fillers).
- Turn off water supply and relieve pressure by actuating bubbler or bottle filler before installation.
- Disconnect power cord before servicing.
- Mount filter head and bracket assembly using provided screws; connect tubing with quick‑connect fittings.
- Insert filter cartridge into filter head and rotate 1/4 turn clockwise to lock.
- Flush filter for 1–2 minutes until water runs clear to remove air and carbon particles.
- If installation is difficult, contact a licensed plumber or authorized Oasis service technician.
Maintenance
- Replace cartridge every 12 months or after rated capacity is reached, whichever comes first.
- Inspect tubing and quick‑connect fittings periodically for leaks or wear.
- Clean basin and sensor areas with non‑abrasive cleaner to maintain performance.
- Use only genuine Oasis replacement cartridges for certified contaminant reduction.