The Oasis PWEBF Retrofit Electric Bottle Filler is designed to upgrade existing Oasis drinking fountains with modern bottle filling capability. Featuring electric sensor activation, it provides hands‑free operation and efficient hydration in public and commercial environments.
Key Installation Requirements:
- Retrofit installation onto compatible Oasis fountain models
- Cold water line only (40–100°F operating temperature)
- Electrical supply: 115V / 60Hz grounded outlet
- Drain connection required for bottle filler basin
- Follow ADA guidelines for installation height and accessibility
Important Notes Before Installing:
- Do not connect to hot water lines
- Always depressurize water line before servicing
- Ensure sensor lens is unobstructed for accurate activation
- Unit is non‑filtered — optional retrofit filtration kits available separately
- Outdoor installation requires winterization or protection in extreme climates
- Secure mounting hardware firmly to resist vandalism
Basic Installation Overview:
- Remove existing fountain trim as required
- Position retrofit bottle filler assembly on parent fountain
- Secure unit using provided mounting brackets and hardware
- Connect cold water supply line to inlet
- Connect drain line from basin to building drain system
- Wire electrical supply to grounded outlet
- Pressurize system slowly and check for leaks
- Test sensor activation for proper flow and operation
For complete specifications and installation guidelines, download the official PWEBF Spec Sheet and the Installation & Maintenance Manual.