Oasis PGN8EBF Installation Guide

The Oasis PGN8EBF is a wall-mounted refrigerated bottle filler with a contactless sensor, an LED lighted alcove, and 8.0 GPH chilling.


Before You Begin

  • Tools: Electric drill/driver, T15 Torx screwdriver and bit, 1/4" nut driver, a small tubing cutter for plastic line, and a way to cut 1-1/4" drain pipe. Wall anchors are not supplied: 3 for the wall hanger and at least 4 for the bottle filler frame.
  • Plumbing: Provide a 3/8" water supply and a 1-1/4" IPS waste connection. The trap and shut-off valve are not furnished. Maximum supply pressure is 100 PSI, so install a pressure regulator if spikes could exceed that.
  • Electrical and ventilation: Provide a 115V outlet with 20A minimum GFCI protection. Allow 4" of clearance per side for ventilation.
  • Safety and support: Some states require a licensed plumber, and all connections must meet local plumbing codes. Do not alter or modify the unit, as this voids the warranty and UL listing.
  • Installation reference: See the installation manual for the rough-in drawing, detailed instructions, and the sensor set-up guide.


Step-by-Step Installation Guide

  1. Mount the chiller: Install the wall hanger per the rough-in drawing using 3 anchors, then hang the chiller unit on it. Install a P-trap in the waste line and a shut-off valve in the supply line.
  2. Connect the water supply: Connect the Water Supply tube to the shut-off valve, using no solder or flare connection, and keep the in-line strainer in place. Rotate the fan blade by hand to confirm it is free, and leave the front panel off.
  3. Mount the bottle filler frame: Set the frame on the top flange of the chiller frame, centered, and secure it to the wall with at least 4 anchors through the slotted holes.
  4. Assemble the drip tray and drain: Attach the drip tray assembly and filter support bracket with T15 screws. Connect the drain elbows and drainpipes from the drip tray to the P-trap, cutting the pipe to length.
  5. Attach the alcove and connect lines: Rest the alcove on the drip tray with the wrapper walls outside the frame, and secure it with 4 T15 screws. Connect the insulated cold water line to the solenoid valve and the IEC connector to the power brick.
  6. Test and finish: Turn on the water, check for leaks, and make sure nothing blocks the fan before plugging in the unit. Once it works properly, install the front cover panel with 2 screws at the base.