The Oasis PCP10EBF is a freestanding refrigerated bottle filler with a contactless sensor, delivering 10.0 GPH of chilled water for indoor use.


Before You Begin

  • Tools and parts: A T15 Torx driver. The drain pipes, elbows, P-trap, and stabilizer bracket are included. Wall anchors, the 1/4" O.D. supply tube, and the drain elbow coupling are not.
  • Plumbing: Provide a 1/4" O.D. water supply at 45 to 100 PSI and a connection to the building drain for the 1-1/2" O.D. drainpipe.
  • Electrical: A 115V outlet on a 20A minimum GFCI device is required, and the unit must be grounded. Check the data plate to confirm the voltage.
  • Clearance and reference: Allow 4" of clearance at the rear, and at the sides if installed in an alcove or corner. See the installation manual for the dimensional drawing and electronics setup.


Step-by-Step Installation Guide

  1. Unpack the unit: Carefully unpack the filler and remove the front panel by taking out the 2 T15 screws at the bottom. Take out the drainpipes, drain elbows, and P-trap packed inside.
  2. Assemble the drain: Connect the drainpipes, elbows, and P-trap to the drip tray tailpiece. Feed the 1-1/2" O.D. P-trap through the snap bushing at the back of the cabinet.
  3. Connect the water supply: Flush the building supply line first. Push the 1/4" O.D. supply tube through the collet of the quick-connect fitting on the back of the unit until it seats firmly at the bottom of the fitting. Cut the tube square, and don't deform it or leave marks on it.
  4. Connect the drain: Attach the 1-1/2" O.D. drainpipe to an elbow coupling (not included) and connect it to the building drain.
  5. Secure and power the unit: Fasten the stabilizer bracket to the unit with the supplied screws, then anchor it to the wall. Spin the fan blade by hand to confirm it's clear, then plug into the GFCI outlet.
  6. Test and finish: Check for leaks. Place a bottle in the alcove to purge air from the tank and lines. The sensor runs for 20 seconds and shuts off, so repeat 2 or 3 times until the stream is steady. Then reinstall the front panel with its 2 screws.