Buying more than 2? Email us for a discount: support@bottlefillingstations.com

FREE SHIPPING

All Products. No Minimums. 

Haws 3612 Installation Guide

Installation

  • Mount pedestal base on a concrete slab (minimum 30" square, 6" thick); ensure compliance with ADA clearances and local codes.
  • Install fountain arms: secure with supplied bolts and nuts, torque to 18 ft‑lbs; configure left/right arms for ADA standing, wheelchair, or child height positions.
  • Attach bottle filler assembly to pedestal using front access panel bolts; install trim rings and fountains on arms.
  • Connect water supply: use 3/8" O.D. copper or plastic tubing with compression fittings; ensure minimum 30 psi (3612) or 40 psi (3612F with filter).
  • Install drain piping: connect 1‑1/2" PVC waste line with supplied compression washers and trap adapters; solvent weld connections per local standards.
  • For 3612F: mount filter bracket and install Everpure 6477 filter kit (3,000‑gallon capacity); operating temperature range 40°F–100°F.
  • Open supply valve, flush system, and check for leaks; reinstall pedestal access plates.
  • For detailed steps, refer to the Haws 3612 installation manual or consult a qualified installer.


Maintenance

  • Periodically clean pushbutton valve strainer; see Haws 5874 Series Valve Operation & Maintenance Manual.
  • Inspect bubbler and bottle filler nozzle strainers; clean or replace if clogged.
  • For 3612F: replace filter cartridge annually or at 3,000 gallons, whichever comes first.
  • Check supply pressure regularly: minimum 30 psi for 3612, 40 psi for 3612F.
  • Inspect fittings, tubing, and drain connections; reseal or tighten as needed.
  • Optional accessories include hose bibs, dog bowl, and modular pedestal arms for custom configurations.
  • For ongoing care, follow the product manual and schedule routine filter changes to ensure consistent performance.

Go to Table of Content