Haws 1011 Installation guide

Installation

  • Position the unit at ADA‑compliant height or adjust dimensions as required by local code.
  • Secure the fountain firmly to the wall using hanger brackets or optional mounting plate; ensure all fasteners engage structural members.
  • Connect the 1/2" IPS supply line with flowing pressure between 30–90 psi; install an inlet filter if sediment or mineral content is high.
  • Attach the 3/8" O.D. push‑in type inlet fitting; cut tubing square, insert fully to depth, and verify watertight connection.
  • Connect the 1‑1/4" O.D. waste tube to the trap provided; maintain proper alignment and check for leaks.
  • Ensure the bubbler valve and push button assembly are properly aligned and tightened; apply thread sealant where specified.
  • Verify clearances and level the unit before final tightening of all fasteners.
  • For detailed steps, refer to the installation manual provided in the package or contact a licensed plumber/electrician.


Maintenance

  • Periodically clean the strainer to maintain proper flow.
  • Inspect the bubbler head, push button, and valve assembly for wear; replace with repair kits if needed.
  • Check water pressure regularly to ensure it remains within the recommended 30–90 psi range.
  • Clean exterior surfaces with mild soap and water; avoid abrasive cleaners.
  • Inspect tubing connections for leaks and re‑seat if necessary.
  • Disconnect power or water supply before servicing to avoid hazards.
  • For service or repairs, consult the manual or a certified service representative.