Installation
- Prepare wall framing and hanger bracket per rough‑in dimensions provided in the package manual.
- Mount hanger bracket securely using all designated holes; add support carrier if wall will not provide adequate support.
- Hang cooler on bracket, ensuring proper engagement with slots on the back panel.
- Remove front panel to access connections; connect water inlet line and install trap on waste outlet.
- If available, connect filter assembly and ensure proper orientation.
- If available, connect refrigeration components and verify ventilation clearance.
- Reconnect panel after plumbing is complete and check for leaks.
- Adjust bubbler stream height as needed; factory set at 45–50 psi.
- For detailed steps, refer to the installation manual provided in the package or contact a licensed plumber.
Maintenance
- Inspect bubbler orifice and regulator periodically; clean or adjust if flow is irregular.
- Check quick‑connect fittings and tubing for leaks; reseat if necessary.
- Clean basin and exterior surfaces with mild, non‑abrasive cleaner.
- If available, replace filter at recommended intervals.
- If available, service refrigeration components as required.
- For service or repairs, consult the manual or a licensed technician.