Buying more than 2? Email us for a discount: support@bottlefillingstations.com

FREE SHIPPING

All Products. No Minimums. 

Elkay LVRC8WSK Installation guide

Installation

  • Install the wall mounting plate securely to the wall at the rough‑in dimensions; ensure adequate support structure or use a fixture carrier if required.
  • Mount the Elkay LVRC8WSK cooler onto the wall bracket and secure with fasteners; connect drain and water inlet per rough‑in diagram.
  • Do not connect power at this stage; leave electrical supply off until water connections are complete.
  • Remove the LVRC bottle filler from carton; feed the power cord and waterline through the hole on top of the cooler basin.
  • Place the bottle filler onto the basin mounting bracket and gasket; tighten the two side screws provided. Install the top cover with supplied screws; do not overtighten.
  • Install insulation on the waterline and connect the 3/8" waterline from the bottle filler to the tee inside the cooler.
  • For filtered models, install the WaterSentry® Plus filter cartridge by inserting into the filter head and rotating clockwise until secure.
  • Turn on water supply and inspect all connections for leaks; correct any leaks before proceeding.
  • Restore electrical power; plug in cooler and bottle filler. Verify green LED filter status and LCD bottle counter display.
  • Test dispensing by pressing the bottle filler button; purge air from the line until flow is steady.
  • Reinstall lower panel on cooler; unit is now ready for use.
  • For detailed steps, refer to the Elkay LVRC8WSK installation manual or contact a licensed plumber/electrician.


Maintenance

  • Replace WaterSentry® Plus filter cartridge when LED indicator shows red or after rated capacity (3,000–6,000 gallons depending on model).
  • Reset filter monitor via program button after replacement; verify green LED illumination.
  • Clean exterior surfaces with mild soap and water; avoid abrasive cleaners that may damage finish.
  • Inspect bubbler stream height and adjust regulator screw as needed; recommended stream height is approximately 1" (25 mm).
  • Check drain connections and drip tray regularly; clean to prevent clogs.
  • Disconnect power and water supply before servicing internal components to avoid hazards.
  • For service or repairs, consult the manual or a certified Elkay service representative.

Go to Table of Content