Elkay EZSTLDDLC Installation Instructions & Guidance

The Elkay EZSTLDDLC is a wall-mount bi-level non-refrigerated drinking fountain designed for on-wall indoor installation, and it ships in one box. Professional installation by a licensed plumber is strongly recommended to ensure proper water supply, drainage, and electrical connections.

Key Installation Requirements:

  • Wall-mounted (on-wall), indoor installation only
  • 115V/60Hz GFCI-protected duplex outlet in a recessed box
  • 3/8" O.D. unplated copper water supply with shut-off (not included), up to 3" out from the wall
  • 20 to 105 psi supply line pressure
  • 1-1/2" trap (not included) and 1-1/2" nominal drain, with the drain stub 2" out from the wall

Important Notes Before Installing the EZSTLDDLC:

  • The unit does not include the shut-off or 1-1/2" trap. These must be supplied separately by the installer.
  • A minimum of 40 psi supply line pressure is required for adequate stream height when both bubblers are used at the same time.
  • Choose the standard or alternate rough-in before mounting, since this sets which side is high and which is low.
  • For a children's ADA installation, reduce the height by 3 inches.
  • A dedicated circuit with load protection sized for 20 amps is highly recommended.
  • If the wall cannot adequately support the unit, add a fixture support carrier such as the MLP200 In-Wall Carrier.
  • Always refer to the official Elkay EZSTLDDLC Spec Sheet for compliance information and product details.

Basic Installation Overview:

  1. Confirm the wall can support the unit (approx. 46 lbs shipping weight).
  2. Remove the hanger bracket from the back of the unit by removing one screw, then anchor it securely to the wall using all six 1/4" mounting holes.
  3. Hang the unit on the bracket, making sure the bracket engages properly in the slots on the back.
  4. Remove the four screws holding the lower front panel, then pull the panel straight down and set it aside.
  5. Connect the water supply according to local codes.
  6. Install the trap on the waste line and tighten the slip nut securely.
  7. Plug in the unit, since it must have electrical power for water to flow.
  8. Check for leaks and test both bubblers. The stream height is factory set at 35 psi, so adjust it if your supply pressure varies greatly.
  9. Replace the front panel and all four screws.