Buying more than 2? Email us for a discount: support@bottlefillingstations.com

FREE SHIPPING

All Products. No Minimums. 

Elkay EZ8WSSSMC Installation guide

Installation


  • Ensure the Elkay EZ8WSSSMC is installed indoors only; ambient temperature must remain between 50°F–100°F (10℃–38℃).
  • Confirm water supply pressure is between 20–105 psi; install a pressure regulator if supply exceeds 105 psi.
  • Shut off the building water supply and disconnect electrical power before beginning installation.
  • Remove the front cover and hanger bracket; fasten the hanger bracket securely to the wall using five screws in 7/16" diameter mounting holes. Use a fixture support carrier if the wall cannot support the load.
  • Hang the cooler onto the bracket and secure with two mounting screws; connect the cooler water line to the shut‑off valve.
  • Remove the bottle filler top cover with a 5/32" Allen wrench; install the wall mounting plate above the basin using six screws through the mounting holes.
  • Feed the bottle filler power cord and 3/8" water line through the basin opening; set the bottle filler onto the basin and attach to the angled tabs on the mounting plate.
  • Slide the bottle filler down to nest in place; reinstall the top cover and secure with screws.
  • Connect the bottle filler water line inside the cooler; connect all drain and water supply fittings per local plumbing codes.
  • Turn on water supply and check for leaks; correct any leaks before proceeding.
  • Plug in the cooler and bottle filler; verify green LED filter status (if equipped) and LCD bottle counter display.
  • Test dispensing by placing a bottle or hand in front of the sensor; purge air from the line until flow is steady.
  • For detailed steps, refer to the Elkay EZ8WSSSMC installation manual or contact a licensed plumber/electrician.


Maintenance


  • Inspect water and drain connections regularly for leaks; reseal or tighten fittings as needed.
  • Replace WaterSentry® Plus filter cartridge when LED indicator shows red or after rated capacity; reset filter monitor via program button.
  • Clean exterior surfaces with mild soap and water; avoid abrasive cleaners that may damage finish.
  • Check bubbler stream height and adjust regulator screw if necessary; recommended stream height is approximately 1" (25 mm).
  • Dispense at least two gallons of water after filter replacement to flush air and carbon particles.
  • Disconnect power and water supply before servicing internal components to avoid hazards.
  • For service or repairs, consult the manual or a certified service representative.


Go to Table of Content