Installation
- Confirm wall structure can support the Elkay EZ™ & LZ™ Versatile Bottle Filling Station; install a fixture support carrier if required.
- Choose configuration: left‑hand high/right‑hand low or left‑low/right‑high. Refrigerated unit must be installed on the right‑hand side.
- Mount hanger brackets securely to wall using all six 7/16" obround holes; maintain proper ADA heights (reduce by 3" for children’s cooler).
- Hang cooler on bracket, ensuring slots engage properly; remove lower front panel by loosening four screws.
- Connect water inlet line to 3/8" O.D. copper tube with shut‑off valve; purge line before connection.
- Install trap: attach slip nut and gasket to cooler waste line; fit into 1‑1/2" O.D. drain stub and tighten securely.
- Install bottle filler: mount wall plate above basin, feed power cord and waterline through basin opening, and secure filler to angled tabs.
- Install WaterSentry® Plus filter cartridge (filtered models) by inserting into filter head and rotating clockwise until secure.
- Turn on water supply; flush at least 1 gallon through bottle filler to purge air and carbon particles; check all connections for leaks.
- Plug cooler and bottle filler into grounded outlet; verify green LED filter status and LCD bottle counter display.
- Adjust bubbler stream height if needed: regulator screw clockwise raises stream, counter‑clockwise lowers stream; target ~6‑1/2" above basin slope.
- Replace lower front panel and secure with screws; ensure wrapper is properly seated inside upper shroud.
- For detailed steps, refer to the Elkay EZ™ & LZ™ Versatile installation manual or contact a licensed plumber/electrician.
Maintenance
- Inspect water and drain connections regularly; reseal or tighten fittings as needed.
- Replace WaterSentry® Plus filter cartridge when LED indicator shows red or after rated capacity; reset filter monitor via program button.
- Clean stainless steel panels with mild soap and water or glass cleaner; avoid abrasive or petroleum‑based cleaners.
- Clean plastic components with mild detergent and soft cloth; antimicrobial properties will not be harmed.
- Check bubbler stream height; adjust regulator screw to maintain approximately 1‑1/2" above guard.
- Disconnect power and water supply before servicing internal components to avoid hazards.
- For service or repairs, consult the manual or a certified service representative.