Installation
- Ensure the wall is structurally sound to support the Elkay Enhanced Single Level ENLZS8WS; install a fixture support carrier if required.
- Maintain proper clearances: 6" minimum from cabinet louvers to wall for ventilation; follow ADA height requirements (reduce by 3" for children’s cooler).
- Remove hanger bracket from back of cooler; mount securely to wall using all six 7/16" obround holes. Maintain 5‑7/8" dimension from wall to trap centerline.
- Hang cooler on bracket, ensuring slots engage properly; secure cooler frame to wall with two screws and washers (not supplied).
- Remove wrapper by loosening security screws (T25); swing wrapper down and out of pivoting bracket for service access. Re‑attach wrapper by aligning bushings and tightening screws angled correctly.
- Connect supply water to filter inlet tube; install trap to waste outlet (1‑1/4" O.D. drain stub, 2" out from wall).
- Install bottle filler: remove top cover with 5/32" Allen wrench, mount wall plate above basin, mark and drill six mounting holes, then secure plate with appropriate fasteners.
- Install gasket and support bracket under bottle filler tower; route 3/8" tubing through gasket to bulkhead fitting in basin, and connect wiring harness to cooler.
- Place bottle filler on hooks of mounting plate; ensure gasket boss fits basin hole; reinstall top cover with screws.
- Install WaterSentry® filter cartridge (3000, 6000, or PFAS filter depending on model) by inserting into filter head and rotating clockwise; label should face forward.
- Turn on water supply and inspect for leaks; correct before restoring power.
- Plug cooler and bottle filler into grounded outlet; verify green LED filter status and LCD bottle counter display.
- Test dispensing by placing bottle or hand in front of sensor; purge air until flow is steady. Flush at least two gallons to clear carbon particles from filter.
- For detailed steps, refer to the Elkay Enhanced ENLZS8WS installation manual or contact a licensed plumber/electrician.
Maintenance
- Inspect water and drain connections regularly; reseal or tighten fittings as needed.
- Replace WaterSentry® filter cartridge when LED indicator shows red or after rated capacity; reset filter monitor via program button.
- Clean stainless steel surfaces with mild detergent and soft cloth; avoid abrasive cleaners or chloride‑based chemicals.
- Clean plastic components with mild detergent and soft cloth; antimicrobial properties will not be harmed.
- Check bubbler stream height; adjust regulator screw to maintain approximately 1‑1/2" above guard.
- Factory temperature control is set at 50°F ± 5°F; adjust cold control if needed for altitude or local conditions.
- Disconnect power and water supply before servicing internal components to avoid hazards.
- For service or repairs, consult the manual or a certified Elkay service representative.