Installation
- Secure hanger brackets to the wall using all six 1/4" mounting holes; add a support carrier if wall strength is insufficient.
- Mount the refrigerated cooler on the right side of the bracket, ensuring proper engagement in the slots. Mount the non‑refrigerated cooler on the opposite side.
- Connect the 3/8" O.D. copper water supply line with shut‑off valve; maximum supply pressure 105 psi.
- Connect the 1‑1/2" O.D. waste outlet to a trap (not furnished), maintaining proper air gap. Check for leaks if drain tube is cut and reassembled.
- Maintain at least 6" clearance from cabinet louvers to wall for ventilation; allow 24" clearance above for service access.
- Install the bottle filler mounting plate securely above the basin, route tubing and wiring harness through the gasket, and connect to cooler bulkhead fittings.
- Plug into a GFCI‑protected electrical outlet; a dedicated 20‑amp circuit is recommended.
- For detailed steps, refer to the installation manual provided in the package or contact a licensed plumber/electrician.
Maintenance
- Replace filters as required; turn off water supply, relieve pressure, unplug unit, and install new cartridge fully clockwise.
- Clean exterior panels with warm soapy water or mild household cleaner; avoid harsh chemicals or abrasives.
- Inspect bubbler, pushbars, solenoid valves, and regulators during service; replace worn components with authentic kits.
- Check drain assembly periodically to ensure proper flow and no leaks.
- Disconnect power before servicing; electrical shock hazard.
- For service or repairs, consult the manual or a certified service representative.