Installation

  • Place the chiller in a well‑ventilated indoor location; maintain at least 4" clearance on all sides.
  • Shut off water supply and disconnect electrical power before starting installation.
  • Connect water inlet and outlet lines using unplated copper tubing; flush lines before connection.
  • Install a shut‑off valve and in‑line strainer between the supply and chiller.
  • Connect electrical wiring to match voltage and phase shown on the serial plate; ensure proper grounding.
  • Turn on water supply, purge air from lines, and check for leaks.
  • Restore electrical power and verify proper operation.
  • For detailed steps, refer to the installation manual provided in the package or contact a licensed plumber.


Maintenance

  • Inspect the chiller twice per year for proper operation and performance.
  • Clean cabinet louvers and condenser fins regularly to maintain ventilation.
  • Check water flow; clean or replace in‑line strainer or filter if restricted.
  • Verify condenser fan spins freely; replace if needed.
  • Adjust water temperature if required (factory set to ~50°F).
  • Motors are lifetime lubricated; no additional lubrication required.
  • For service or repairs, consult the manual or a licensed technician.