The Elkay 98543C Electrical Package Kit is an OEM replacement assembly for EZH2O® bottle filling stations and coolers. It restores proper sensor activation, LED display, and control board functionality in non‑enhanced models.
Key Installation Requirements:
- Disconnect electrical power before servicing to avoid shock hazard
- Shut off water supply prior to installation
- Mount sensor board, LED board, and control board securely using supplied hardware
- Connect wiring harness to sensor, LED, and control boards
- Ensure lens and sensor are properly aligned for accurate activation
- Verify all connections are tight and free of debris
Important Notes Before Installing:
- Only install on compatible non‑enhanced EZH2O® models — not for “P” enhanced units
- Indoor installation only; do not use outdoors or in vandal‑resistant units
- Qualified service personnel should perform replacement to ensure safety
- Always depressurize the system before disconnecting wiring or components
- Provide adequate clearance for servicing and avoid pinching or straining wires
- Use genuine Elkay parts to maintain warranty and certification
Basic Installation Overview:
- Disconnect electrical power and shut off water supply
- Remove front panel to access electrical assembly
- Disconnect old boards, lens, and wiring harness
- Install new sensor board, LED board, and control board using supplied spacers and screws
- Attach lens and reconnect wiring harness
- Restore water supply and electrical power
- Test bottle filler to confirm proper sensor activation, LED display, and counter operation
For complete step‑by‑step instructions, refer to Elkay EZH2O® service manuals and OEM documentation for electrical kit replacement.