Wilkins ZW4004ILGSS-U | 2 1/2" Fire Control PRV, Grooved, Supervisory Switch
Wilkins ZW4004ILGSS-U | 2 1/2" Fire Control PRV, Grooved, Supervisory Switch is backordered and will ship as soon as it is back in stock.
Shipping
Shipping
🚚✨ Free Shipping in the Continental U.S.
All Products. No Minimums.
Estimated Shipping Times:
Important Note on Delivery Times
All shipping estimates provided are approximate only. While we always strive to meet or exceed your delivery expectations, we cannot guarantee the exact delivery times listed.
For time-sensitive orders, please contact us directly so we can provide a more accurate lead time estimate based on your specific requirements.
Same Day Shipping
All in stock orders received before 3PM EST will ship the same day. Orders received after 3PM EST will ship the following business day.
Water Filters, Hand Dryers, & Indoor Bottle Fillers are our most popular in stock items.
Outdoor Tubular Drinking Fountains
Evergreen normally ships in 5-15 days. Black, Gray and Blue ship in 2-4 weeks.
Ice Machines
In stock units ship within 48 hours. Other units normally ship in 2-4 weeks.
Other
Orders that ship directly from a manufacturer normally have a firm shipping estimate but those dates are subject to change due to manufacturer production, inventory or shipping. We do our best to estimate ship dates but orders shipping directly from the manufacturer can have unexpected delays. We will confirm tracking information when orders ship directly from a manufacturer but may not have updates or estimates beyond the original estimate. Once your order is placed with the manufacturer, it may not be able to be cancelled even if it hasn't shipped yet.
Please contact support@bottlefillingstations.com to confirm delivery time for a specific product or quantity. Or to inquire about an existing order.
Special Case Shipping Rates
Please note that shipping rates are subject to change at any time. We reserve the right to charge an additional fee in addition to the regularly advertised shipping fee for shipping to remote areas not easily accessible by typical freight carrier means (i.e. islands only accessible by ferry). If your order falls into this category, you will be notified upon receipt of your order, and have the option to complete the purchase with additional fee or to cancel the order. Please note, these instances are very rare, as most locations are reachable by regular freight. If you have any questions, please contact us!
Key Terms & Conditions
Exceptions may apply to islands and other remote territories.
All orders shipped by the carrier of our choice.
The Wilkins ZW4004ILGSS-U is a UL Listed automatic fire control pressure reducing valve designed for fire sprinkler and standpipe systems, regulating pressure under both flow and no-flow conditions.
Key Specifications:
- Size: 2 1/2 Inches
- Maximum Inlet Pressure: 400 psi
- Notable Certifications: UL Listed, C-UL Listed, NYC MEA 325-06-E
- End Connections: Grooved inlet/outlet connections
- Configuration: In-line globe type body
Other Related Variants:
- ZW4004ILGSS-R: Pressure setting R
- ZW4004ILGSS-S: Pressure setting S
- ZW4004ILGSS-T: Pressure setting T
Materials:
- Cast bronze body (ASTM B 584)
- Buna Nitrile elastomers (FDA approved)
- EPDM elastomers (FDA approved)
Typical Installation:
The Zurn ZW4004ILGSS-U is listed as a floor control valve, indicating valve, and check valve in automatic sprinkler systems as well as a standpipe valve for CLASS I and CLASS III systems where pressure regulation is required.
Standards Compliance:
UL Listed; C-UL Listed; NYC MEA 325-06-E; City of Los Angeles Approved; California State Fire Marshal Listed
Features & Benefits:
- Factory Set Non-Adjustable: Ensures consistent pressure control with factory calibrated settings that cannot be tampered with in the field.
- Integral Supervisory Switch: Built-in listed supervisory switch (3 A @ 125 VAC) monitors valve position and provides tamper-resistant protection.
- Dual Condition Regulation: Maintains accurate pressure regulation under both flowing and static conditions for optimal fire protection system performance.
- Grooved Connections: AWWA C606 grooved inlet and outlet connections allow for faster installation and system modifications.
FAQ
Q: What is the difference between pressure settings U, R, S, and T on the Wilkins ZW4004ILGSS series?
A: Each pressure setting letter corresponds to a different factory-calibrated outlet pressure profile. Setting U has a maximum rated inlet pressure of 200 psi, while settings R, S, and T have progressively different pressure ranges as shown in the residual pressure charts.
Q: Can the Zurn ZW4004ILGSS-U pressure setting be adjusted in the field?
A: No, the Wilkins ZW4004ILGSS-U is factory set and non-field adjustable to ensure consistent, tamper-proof pressure regulation in fire protection systems.
Q: What is the purpose of the integral supervisory switch on this valve?
A: The supervisory switch monitors valve position and provides alarm signals to fire alarm control panels if the valve is closed or tampered with, ensuring continuous system supervision as required by fire codes.
NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.