Wilkins 34-375ST | 3/4" Stainless Steel Reduced Pressure Backflow Preventer
Wilkins 34-375ST | 3/4" Stainless Steel Reduced Pressure Backflow Preventer is backordered and will ship as soon as it is back in stock.
Shipping
Shipping
🚚✨ Free Shipping in the Continental U.S.
All Products. No Minimums.
Estimated Shipping Times:
Important Note on Delivery Times
All shipping estimates provided are approximate only. While we always strive to meet or exceed your delivery expectations, we cannot guarantee the exact delivery times listed.
For time-sensitive orders, please contact us directly so we can provide a more accurate lead time estimate based on your specific requirements.
Same Day Shipping
All in stock orders received before 3PM EST will ship the same day. Orders received after 3PM EST will ship the following business day.
Water Filters, Hand Dryers, & Indoor Bottle Fillers are our most popular in stock items.
Outdoor Tubular Drinking Fountains
Evergreen normally ships in 5-15 days. Black, Gray and Blue ship in 2-4 weeks.
Ice Machines
In stock units ship within 48 hours. Other units normally ship in 2-4 weeks.
Other
Orders that ship directly from a manufacturer normally have a firm shipping estimate but those dates are subject to change due to manufacturer production, inventory or shipping. We do our best to estimate ship dates but orders shipping directly from the manufacturer can have unexpected delays. We will confirm tracking information when orders ship directly from a manufacturer but may not have updates or estimates beyond the original estimate. Once your order is placed with the manufacturer, it may not be able to be cancelled even if it hasn't shipped yet.
Please contact support@bottlefillingstations.com to confirm delivery time for a specific product or quantity. Or to inquire about an existing order.
Special Case Shipping Rates
Please note that shipping rates are subject to change at any time. We reserve the right to charge an additional fee in addition to the regularly advertised shipping fee for shipping to remote areas not easily accessible by typical freight carrier means (i.e. islands only accessible by ferry). If your order falls into this category, you will be notified upon receipt of your order, and have the option to complete the purchase with additional fee or to cancel the order. Please note, these instances are very rare, as most locations are reachable by regular freight. If you have any questions, please contact us!
Key Terms & Conditions
Exceptions may apply to islands and other remote territories.
All orders shipped by the carrier of our choice.
NOTICE: Product images may vary from the actual item due to differences in size or configuration options.
The Wilkins 34-375ST is a stainless steel reduced pressure principle backflow preventer designed to protect potable water systems from contamination where health hazards exist.
Key Specifications:
- Size: 3/4 Inches
- Maximum Working Water Pressure: 175 PSI
- Maximum Working Water Temperature: 180°F
- Notable Certifications: ASSE 1013, CSA B64.4, NSF/ANSI/CAN 61
- End Connections: Threaded FNPT
Other Related Variants:
- 12-375ST: 1/2 Inch version
- 1-375ST: 1 Inch model size
Materials:
- Reinforced Nylon Housing (FDA approved)
- Stainless Steel Ball Valves (ASTM A351 CF-8M)
- Stainless Steel Fasteners (300 Series)
- Stainless Steel Springs (300 Series)
- Stainless Steel Struts (300 Series)
- Delrin Internals
- Nylon Internals
- Silicone Elastomers (FDA Approved)
- Buna Nitrile Elastomers (FDA Approved)
Typical Installation:
Designed for installation on potable water lines to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. The Zurn 34-375ST provides protection where a potential health hazard exists. The valve's stainless steel construction is ideal in systems that utilize liquids corrosive to copper alloys. Potential applications include medical diagnostic equipment, food processing, distilleries, breweries, and applications requiring lead-free valves. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.
Standards Compliance:
ASSE Listed 1013; CSA B64.4; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; NSF/ANSI/CAN 61
Features & Benefits:
- Corrosion-Resistant Construction: Stainless steel construction ideal for systems with liquids corrosive to copper alloys, ensuring long-lasting durability.
- Health Hazard Protection: Provides reliable protection against both backsiphonage and backpressure where potential health hazards exist.
- Lead-Free Compliance: Meets 0.25% maximum weighted average lead content requirements, ideal for applications requiring lead-free valves.
- Versatile Applications: Perfect for medical diagnostic equipment, food processing, distilleries, breweries, and other demanding environments.
FAQ
Q: What is the maximum working pressure and temperature for the Wilkins 34-375ST?
A: The Zurn 34-375ST has a maximum working water pressure of 175 PSI and a maximum working water temperature of 180°F.
Q: What certifications does this backflow preventer meet?
A: This unit is ASSE Listed 1013, CSA B64.4 compliant, approved by the Foundation for Cross Connection Control and Hydraulic Research at USC, and meets NSF/ANSI/CAN 61 requirements.
Q: What are the installation height requirements?
A: The assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance.
NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.