Wilkins 2-950XLT2 | Double Check Backflow Preventer
Wilkins 2-950XLT2 | Double Check Backflow Preventer is backordered and will ship as soon as it is back in stock.
Shipping
Shipping
🚚✨ Free Shipping in the Continental U.S.
All Products. No Minimums.
Estimated Shipping Times:
Important Note on Delivery Times
All shipping estimates provided are approximate only. While we always strive to meet or exceed your delivery expectations, we cannot guarantee the exact delivery times listed.
For time-sensitive orders, please contact us directly so we can provide a more accurate lead time estimate based on your specific requirements.
Same Day Shipping
All in stock orders received before 3PM EST will ship the same day. Orders received after 3PM EST will ship the following business day.
Water Filters, Hand Dryers, & Indoor Bottle Fillers are our most popular in stock items.
Outdoor Tubular Drinking Fountains
Evergreen normally ships in 5-15 days. Black, Gray and Blue ship in 2-4 weeks.
Ice Machines
In stock units ship within 48 hours. Other units normally ship in 2-4 weeks.
Other
Orders that ship directly from a manufacturer normally have a firm shipping estimate but those dates are subject to change due to manufacturer production, inventory or shipping. We do our best to estimate ship dates but orders shipping directly from the manufacturer can have unexpected delays. We will confirm tracking information when orders ship directly from a manufacturer but may not have updates or estimates beyond the original estimate. Once your order is placed with the manufacturer, it may not be able to be cancelled even if it hasn't shipped yet.
Please contact support@bottlefillingstations.com to confirm delivery time for a specific product or quantity. Or to inquire about an existing order.
Special Case Shipping Rates
Please note that shipping rates are subject to change at any time. We reserve the right to charge an additional fee in addition to the regularly advertised shipping fee for shipping to remote areas not easily accessible by typical freight carrier means (i.e. islands only accessible by ferry). If your order falls into this category, you will be notified upon receipt of your order, and have the option to complete the purchase with additional fee or to cancel the order. Please note, these instances are very rare, as most locations are reachable by regular freight. If you have any questions, please contact us!
Key Terms & Conditions
Exceptions may apply to islands and other remote territories.
All orders shipped by the carrier of our choice.
The Wilkins 2-950XLT2 is a top-access double check valve assembly designed for potable water protection against backsiphonage and backpressure in non-health hazard applications.
Key Specifications:
- Size: 2 Inches
- Maximum Working Water Pressure: 175 PSI
- Maximum Working Water Temperature: 180°F
- Notable Certifications: ASSE 1015, cUPC, CSA B64.5
- End Connections: Threaded ANSI B1.20.1
Other Related Variants:
- 34-950XLT2: 3/4 Inches version
- 1-950XLT2: 1 Inches version
- 114-950XLT2: 1 1/4 Inches version
- 112-950XLT2: 1 1/2 Inches version
Materials:
- Main valve body: Low Lead Cast Bronze ASTM B 584
- Access covers: Low Lead Cast Bronze ASTM B 584
- Fasteners: Stainless Steel, 300 Series
- Elastomers: Silicone and Buna Nitrile
- Polymers: Noryl™
- Springs: Stainless steel, 300 series
- Test cock cover: Plastic
- Ball valve handles: Stainless steel
Typical Installation:
Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. If installed below grade, be certain adequate drainage is provided to prevent the device from being submerged.
Standards Compliance:
ASSE Listed 1015; cUPC Listed; CSA Certified B64.5; AWWA Compliant C510; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (Horizontal installations only); NSF/ANSI/CAN 61 and 372
Features & Benefits:
- Top-Access Design: Checks located at 45° angle allow easy maintenance from the top without removing the device from the line, reducing downtime and labor costs.
- Lead-Free Compliance: Meets NSF/ANSI/CAN 61 and 372 standards with less than 0.25% weighted average lead content for safe potable water applications.
- Durable Construction: Low lead cast bronze body with stainless steel fasteners and springs ensures long-lasting performance in demanding commercial and municipal installations.
- Protected Test Cocks: Test cock plugs prevent fouling from insects, dirt, and debris while allowing convenient access for testing and inspection.
FAQ
Q: Can the Zurn 2-950XLT2 be installed in vertical positions?
A: Yes, the Zurn 2-950XLT2 is certified for both horizontal and vertical flow-up installations per ASSE 1015, cUPC, and CSA B64.5 standards. Note that the USC Foundation approval applies to horizontal installations only.
Q: What is the maximum working pressure for this backflow preventer?
A: The maximum working water pressure is 175 PSI with a hydrostatic test pressure of 350 PSI and maximum working temperature of 180°F.
Q: Does the Wilkins 2-950XLT2 require a strainer?
A: A strainer is optional. The unit can be ordered with suffix "S" to include a Model SXL lead-free bronze "Y" type strainer for enhanced protection against debris.
NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.
"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us
Always consult with a licensed professional and check local codes before installation. For further details, check the Owners Manual.
Contact us at support@bottlefillingstations.com with any questions.