Zurn Wilkins  |  SKU: 112-975XL3U

Wilkins 112-975XL3U | 1 1/2" RP Backflow Preventer with Union Ball Valves

Regular price $ 1,751.99

Shipping

🚚✨ Free Shipping in the Continental U.S. 
All Products. No Minimums.


Estimated Shipping Times:


Important Note on Delivery Times

All shipping estimates provided are approximate only. While we always strive to meet or exceed your delivery expectations, we cannot guarantee the exact delivery times listed.

For time-sensitive orders, please contact us directly so we can provide a more accurate lead time estimate based on your specific requirements.

Same Day Shipping

All in stock orders received before 3PM EST will ship the same day. Orders received after 3PM EST will ship the following business day. 

Water Filters, Hand Dryers, & Indoor Bottle Fillers are our most popular in stock items. 

Outdoor Tubular Drinking Fountains

Evergreen normally ships in 5-15 days. Black, Gray and Blue ship in 2-4 weeks. 

Ice Machines

In stock units ship within 48 hours. Other units normally ship in 2-4 weeks.

Other

Orders that ship directly from a manufacturer normally have a firm shipping estimate but those dates are subject to change due to manufacturer production, inventory or shipping. We do our best to estimate ship dates but orders shipping directly from the manufacturer can have unexpected delays. We will confirm tracking information when orders ship directly from a manufacturer but may not have updates or estimates beyond the original estimate. Once your order is placed with the manufacturer, it may not be able to be cancelled even if it hasn't shipped yet.  

Please contact support@bottlefillingstations.com to confirm delivery time for a specific product or quantity. Or to inquire about an existing order. 


Special Case Shipping Rates

 

Please note that shipping rates are subject to change at any time.  We reserve the right to charge an additional fee in addition to the regularly advertised shipping fee for shipping to remote areas not easily accessible by typical freight carrier means (i.e. islands only accessible by ferry). If your order falls into this category, you will be notified upon receipt of your order, and have the option to complete the purchase with additional fee or to cancel the order.  Please note, these instances are very rare, as most locations are reachable by regular freight. If you have any questions, please contact us! 


Key Terms & Conditions

 

Exceptions may apply to islands and other remote territories.

All orders shipped by the carrier of our choice.  

 

 

 


 

 

 

NOTICE: Product images may vary from the actual item due to differences in size or configuration options.

The Wilkins 112-975XL3U is a 1 1/2" reduced pressure principle backflow prevention assembly designed to protect potable water systems against health hazards.

 

Key Specifications:

  • Size: 1 1/2 Inches
  • Maximum Working Pressure: 175 PSI
  • Maximum Working Temperature: 180°F
  • Notable Certifications: ASSE 1013, cUPC, CSA B64.4
  • End Connections: Female NPT Threaded

 

Other Related Variants:

  • 1-975XL3U: 1 Inch version with union ball valves
  • 2-975XL3U: 2 Inch version with union ball valves
  • 34-975XL3U: 3/4 Inch version with union ball valves

 

Materials:

  • Main valve body: Low Lead Cast Bronze ASTM B584
  • Access covers: Low Lead Cast Bronze ASTM B584
  • Fasteners: 300 Series Stainless Steel
  • Elastomers: Silicone (FDA Approved)
  • Elastomers: Buna Nitrile (FDA Approved)
  • Polymers: Noryl™
  • Springs: 300 Series Stainless Steel
  • Ball valve handles: Stainless Steel

 

Typical Installation:

Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.

 

Standards Compliance:

ASSE Listed 1013; cUPC Listed; CSA Certified B64.4; UL Classified; C-UL Classified; AWWA Compliant C511; Meets NSF/ANSI/CAN 61 & 372

 

Features & Benefits:

  • Lead-Free Protection: Certified to NSF/ANSI/CAN 61 and 372 with less than 0.25% weighted average lead content for safe potable water applications.
  • Dual Protection Design: Protects against both backsiphonage and backpressure of contaminated water into potable water supply systems.
  • Easy Maintenance Access: First and second checks accessible through single cover without removing relief valve or entire device from line.
  • Durable Construction: Low lead cast bronze body with 300 series stainless steel fasteners and springs ensures long-lasting performance.

 

FAQ

 

Q: What pressure range is the Zurn 112-975XL3U rated for?

A: The Zurn 112-975XL3U operates within a working pressure range of 25 PSI minimum to 175 PSI maximum, with a hydrostatic test pressure of 350 PSI.

Q: What is the difference between the 112-975XL3U and standard 975XL3 models?

A: The "U" suffix indicates the unit comes equipped with union ball valves instead of standard ball valves, providing easier installation and removal for maintenance.

Q: Can this backflow preventer be installed outdoors?

A: Yes, the unit can be installed outdoors but must be protected with a proper enclosure and installed 12" to 30" above adequate drains to prevent submersion and freeze damage.

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.