Buying more than 2? Email us for a discount: support@bottlefillingstations.com

FREE SHIPPING

All Products. No Minimums. 

Everpure EV927086 Installation guide

Installation

  • Turn off cold water supply and relieve pressure by opening faucet; disconnect power if connected to an appliance.
  • Lift the handle of the built‑in shut‑off valve on the QL3 filter head to stop water flow.
  • Hold filter head firmly; align the lug on the Everpure EV927086 cartridge with the label on the head.
  • Insert EV927086 cartridge upward into head; rotate clockwise about 1/4 turn until fully seated.
  • Lower shut‑off valve handle to restore water flow; open faucet and flush for at least 3 minutes to purge air and carbon particles.
  • Check all connections for leaks; tighten fittings if necessary.
  • Activate Everpure filter timer (Timestrip®) by pressing bubble until red line appears; adhere timer near installation site for replacement tracking.
  • For detailed steps, refer to the Everpure PBS‑400 installation guide or consult a qualified plumber.


Maintenance

  • Replace the Everpure EV927086 cartridge every 3,000 gallons or 12 months, whichever comes first.
  • Inspect braided tubing and fittings regularly; reseal or tighten connections as needed.
  • Flush system after each cartridge replacement to ensure clean water flow.
  • System is certified to NSF/ANSI 42 & 53 for chlorine, particulate, lead, and cyst reduction; performance may vary depending on local water conditions.
  • Do not use with microbiologically unsafe water or water of unknown quality without adequate disinfection before or after the system.
  • Disconnect power and water supply before servicing connected appliances to avoid hazards.
  • For ongoing care or troubleshooting, please refer to the product manual or seek assistance from a professional installer or local water filtration specialist.

Go to Table of Content