{"product_id":"zurn-wilkins-34-975xl2ft-backflow-preventer-34-inches-with-sae-test-fitting","title":"Wilkins 34-975XL2FT | Backflow Preventer, 3\/4 Inches with SAE Test Fitting","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Wilkins 34-975XL2FT is a reduced pressure principle backflow prevention assembly designed to protect potable water supplies from contamination.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 3\/4 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Pressure:\u003c\/strong\u003e 175 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Temperature:\u003c\/strong\u003e 180°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1013, cUPC, CSA B64.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e Threaded ANSI B1.20.1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e112-975XL2FT:\u003c\/strong\u003e 1 1\/4 Inches version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-975XL2FT:\u003c\/strong\u003e 1 Inches version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-975XL2FT:\u003c\/strong\u003e 2 Inches version\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBody: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eAccess Covers: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eFasteners: 300 Series Stainless Steel\u003c\/li\u003e\n\u003cli\u003eElastomers: Silicone and Buna Nitrile\u003c\/li\u003e\n\u003cli\u003ePolymers: Noryl™\u003c\/li\u003e\n\u003cli\u003eSprings: 300 Series Stainless Steel\u003c\/li\u003e\n\u003cli\u003eBall Valve Handles: Stainless Steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eLocal codes shall govern installation requirements. The Zurn 34-975XL2FT shall be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. For indoor installations, an air gap fitting is required.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eASSE 1013; cUPC; CSA B64.4; AWWA C511; Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; NSF\/ANSI\/CAN 61 \u0026amp; 372; UL Classified; C-UL Classified\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHealth Hazard Protection:\u003c\/strong\u003e Provides protection against backsiphonage and backpressure where potential health hazards exist in potable water systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free Compliance:\u003c\/strong\u003e Constructed with low lead cast bronze meeting NSF\/ANSI\/CAN 372 standards for safe drinking water applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port Ball Valves:\u003c\/strong\u003e Equipped with full port QT ball valves for maximum flow capacity and easy shutoff during maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral SAE Test Fitting:\u003c\/strong\u003e Features built-in male 45° flare SAE test fittings for convenient testing and compliance verification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the minimum and maximum installation height for the Wilkins 34-975XL2FT?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The assembly must be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is an air gap fitting required for the Zurn 34-975XL2FT?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, for indoor installations, an air gap adapter is required. Outdoor installations require proper drainage and protective enclosure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum working pressure and temperature for this backflow preventer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 34-975XL2FT is rated for a maximum working water pressure of 175 PSI and maximum working water temperature of 180°F.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003cstrong\u003eNOTICE:\u003c\/strong\u003e Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ci\u003e \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com | \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e Contact us \u003c\/a\u003e \u003c\/i\u003e\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914918793279,"sku":"34-975XL2FT","price":1077.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/34-975XL2_AF.jpg?v=1770997524","url":"https:\/\/bottlefillingstations.com\/products\/zurn-wilkins-34-975xl2ft-backflow-preventer-34-inches-with-sae-test-fitting","provider":"BottleFillingStations.com","version":"1.0","type":"link"}