{"product_id":"zurn-wilkins-2-500xlhlr-water-pressure-reducing-valve-with-bypass-check","title":"Wilkins 2-500XLHLR | Water Pressure Reducing Valve with Bypass Check","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\nThe Wilkins 2-500XLHLR is a water pressure reducing valve with integral by-pass check valve designed for industrial and commercial water systems requiring reliable pressure control and thermal expansion protection.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 2 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Temperature:\u003c\/strong\u003e 140°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1003, cUPC, CSA B356\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Single Union FNPT\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e112-500XLHLR:\u003c\/strong\u003e 1 1\/2 Inches size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e114-500XLHLR:\u003c\/strong\u003e 1 1\/4 Inches size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-500XLHLR:\u003c\/strong\u003e 1 Inch size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e34-500XLHLR:\u003c\/strong\u003e 3\/4 Inches size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-500XLHLR:\u003c\/strong\u003e 3 Inches size\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain Valve Body: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eAccess Covers: Low Lead Cast Bronze ASTM B 584 \/ Low Lead Brass\u003c\/li\u003e\n\u003cli\u003eFasteners: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eStem \u0026amp; Plunger: Low Lead Cast Bronze ASTM B 584 \/ Low Lead Brass\u003c\/li\u003e\n\u003cli\u003eElastomers: Buna Nitrile (FDA approved) \/ EPDM (FDA approved)\u003c\/li\u003e\n\u003cli\u003eCap Gaskets: Natural Vulcanized Fibre \/ Acetal (Delrin™ 500)\u003c\/li\u003e\n\u003cli\u003eSprings: Oil Tempered Wire, ASTM A 229\u003c\/li\u003e\n\u003cli\u003eSeat: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nLocal codes shall govern installation requirements. The assembly shall be mounted in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. The assembly shall be installed with sufficient side clearance for testing and maintenance. The Model 500XL may be installed in any position. If installed in a pit, vault, or inside application, specify the \"SC\" sealed cage option. Multiple installations are recommend for wide demand variations or where the desired pressure reduction is more than 3 to 1 (i.e.: 150 psi inlet reduced to 50 psi outlet).\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nASSE Listed 1003; cUPC Listed; CSA Certified B356; City of Los Angeles Approved; NSF\/ANSI\/CAN 61; NSF\/ANSI\/CAN 372\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Flow Capacity:\u003c\/strong\u003e Balanced piston design provides smooth response to system flow demand changes, ideal for industrial and commercial applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Expansion Protection:\u003c\/strong\u003e Direct acting integral by-pass design prevents excessive system pressure buildup caused by thermal expansion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Pressure Range:\u003c\/strong\u003e The Zurn 2-500XLHLR features HLR option with 10 psi to 125 psi spring range, factory set at 50 psi for versatile applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Installation:\u003c\/strong\u003e May be installed in any position with accessible maintenance without removing the body from the line.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What pressure reduction ratio is recommended for the Zurn Wilkins 2-500XLHLR?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The valve is recommended for pressure reductions not exceeding a 3:1 ratio. For greater reductions, multiple installations are recommended.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can the Wilkins 2-500XLHLR be installed in a pit or vault application?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, when installed in a pit, vault, or inside application, specify the \"SC\" sealed cage option for proper protection.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How do I adjust the outlet pressure on the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: A downstream pressure gauge must be used when adjusting the valve. Do not bottom the adjustment bolt on the bell housing. Adjust while monitoring the downstream gauge for correct pressure setting.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\n\u003cspan\u003e\n\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\nDo not use with water that is unsafe or of unknown quality without adequate\ndisinfection either before or after the system.\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\n\u003ci\u003e\n\"Hydrate Everyone, Everywhere!\" BottleFillingStations.com |\n\u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e\nContact us\n\u003c\/a\u003e\n\u003c\/i\u003e\n\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914915909695,"sku":"2-500XLHLR","price":2912.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/1-500XL-01-01_3d4b8979-0f36-402c-a4af-c64c46c30086.png?v=1770569100","url":"https:\/\/bottlefillingstations.com\/products\/zurn-wilkins-2-500xlhlr-water-pressure-reducing-valve-with-bypass-check","provider":"BottleFillingStations.com","version":"1.0","type":"link"}