{"product_id":"zurn-wilkins-14-975xl2-reduced-pressure-backflow-preventer-14-inches","title":"Wilkins 14-975XL2 | Reduced Pressure Backflow Preventer, 1\/4 Inches","description":"\u003cp\u003eThe Wilkins 14-975XL2 is a reduced pressure principle backflow prevention assembly designed to protect potable water lines against backsiphonage and backpressure where potential health hazards exist.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 1\/4 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Pressure:\u003c\/strong\u003e 175 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Temperature:\u003c\/strong\u003e 180°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1013, IAPMO Listed, CSA B64.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e Threaded ANSI B1.20.1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/bottlefillingstations.com\/products\/zurn-wilkins-12-975xl2-reduced-pressure-backflow-preventer-12\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003e12-975XL2:\u003c\/strong\u003e\u003c\/a\u003e 1\/2 Inch model size\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/bottlefillingstations.com\/products\/zurn-wilkins-38-975xl2-reduced-pressure-backflow-preventer-38-inches\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003e38-975XL2:\u003c\/strong\u003e\u003c\/a\u003e 3\/8 Inch model size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain Valve Body: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eAccess Covers: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eFasteners: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eElastomers: Silicone (FDA Approved)\u003c\/li\u003e\n\u003cli\u003eElastomers: Buna Nitrile (FDA Approved)\u003c\/li\u003e\n\u003cli\u003ePolymers: Noryl™\u003c\/li\u003e\n\u003cli\u003eSprings: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eBall Valve Handles: Stainless Steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eLocal codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged or where relief valve discharge could cause damage. If installed indoors, the installation shall be supplied with an air gap and \"Y\" type strainer.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003eASSE Listed 1013; IAPMO Listed; CSA Certified B64.4; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; Meets the requirements of NSF\/ANSI 61 (0.25% MAX. WEIGHTED AVERAGE LEAD CONTENT)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free Construction:\u003c\/strong\u003e Meets NSF\/ANSI 61 standards with 0.25% maximum weighted average lead content, ideal for potable water applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHealth Hazard Protection:\u003c\/strong\u003e Provides protection against both backsiphonage and backpressure of contaminated water where potential health hazards exist.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port QT Ball Valves:\u003c\/strong\u003e Standard full port QT ball valves included for reliable shut-off and ease of testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessible Check Valves:\u003c\/strong\u003e Checks oriented at 45° angle upward and accessible for maintenance without removing the relief valve or entire device from the line.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the required installation height for the Zurn 14-975XL2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The Wilkins 14-975XL2 must be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is an air gap required for indoor installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, for indoor installations, the Zurn 14-975XL2 installation shall be supplied with an air gap and \"Y\" type strainer as specified in the installation requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum working pressure and temperature for this assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The assembly has a maximum working water pressure of 175 PSI and a maximum working water temperature of 180°F, with a hydrostatic test pressure of 350 PSI.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003cstrong\u003eNOTICE:\u003c\/strong\u003e Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ci\u003e \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com | \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e Contact us \u003c\/a\u003e \u003c\/i\u003e\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914915844159,"sku":"14-975XL2","price":870.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/14-975XL2_AF.jpg?v=1771003918","url":"https:\/\/bottlefillingstations.com\/products\/zurn-wilkins-14-975xl2-reduced-pressure-backflow-preventer-14-inches","provider":"BottleFillingStations.com","version":"1.0","type":"link"}