{"product_id":"zurn-wilkins-12-600xlc-12-water-pressure-reducing-valve-with-strainer","title":"Wilkins 12-600XLC | 1\/2\" Water Pressure Reducing Valve with Strainer","description":"\u003cp\u003e\nThe Wilkins 1\/2-600XLC is a water pressure reducing valve with integral by-pass check valve and strainer, designed for residential and commercial potable water systems requiring reliable pressure control and frequent cleaning due to sediment.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 1\/2 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Water Temperature:\u003c\/strong\u003e 140°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e ASSE 1003, IAPMO, CSA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Copper Sweat Connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e34-600XLC:\u003c\/strong\u003e 3\/4 Inch model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-600XLC:\u003c\/strong\u003e 1 Inch model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e114-600XLC:\u003c\/strong\u003e 1 1\/4 Inches model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e112-600XLC:\u003c\/strong\u003e 1 1\/2 Inches model size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-600XLC:\u003c\/strong\u003e 2 Inches model size\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain valve body: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n\u003cli\u003eAccess covers: Low Lead Cast Bronze ASTM B 584 \/ Low Lead Brass\u003c\/li\u003e\n\u003cli\u003eFasteners: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eStem \u0026amp; plunger: Low Lead Cast Bronze ASTM B 584 \/ Low Lead Brass\u003c\/li\u003e\n\u003cli\u003eElastomers: Buna Nitrile (FDA Approved) \/ EPDM (FDA Approved)\u003c\/li\u003e\n\u003cli\u003eCap gaskets: Natural Vulcanized Fibre \/ Acetal (Delrin™)\u003c\/li\u003e\n\u003cli\u003eStrainer screen: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003cli\u003eSeat: Stainless Steel, 300 Series\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nLocal codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted in accordance with the latest edition of the Uniform Plumbing Code. The Model 600XL may be installed in any position. If installed in a pit, vault or inside application, specify the \"SC\" sealed cage option. Multiple installations are recommended for wide demand variations or where the desired pressure reduction is more than 4 to 1 (i.e.: 200 psi inlet reduced to 50 psi outlet). Anytime a reducing valve is adjusted, a pressure gauge must be used downstream to verify correct pressure setting. Do not bottom adjustment bolt on bell housing.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nASSE Listed 1003; IAPMO Listed; CSA Certified; City of Los Angeles Approved; NSF\/ANSI\/CAN 61\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBalanced Piston Design:\u003c\/strong\u003e Provides smooth and responsive reaction to system flow demand changes while protecting against inlet pressure variations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral By-Pass Check Valve:\u003c\/strong\u003e Prevents buildup of excessive system pressure caused by thermal expansion, protecting the water system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral Strainer:\u003c\/strong\u003e Makes the Zurn 12-600XLC most suitable for systems requiring frequent cleaning because of sediment and debris.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Installation:\u003c\/strong\u003e Can be installed in any position, with sealed cage option available for pit, vault, or indoor applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can the Zurn Wilkins 12-600XLC be installed in any orientation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the Model 600XL may be installed in any position. For pit, vault, or indoor applications, specify the \"SC\" sealed cage option.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What pressure reduction ratio is recommended for the Wilkins 12-600XLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Multiple valve installations are recommended for wide demand variations or where the desired pressure reduction is more than 4 to 1 (e.g., 200 psi inlet reduced to 50 psi outlet).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How should I adjust the downstream pressure on this valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Always use a downstream pressure gauge to verify correct pressure setting when adjusting the reducing valve. Do not bottom the adjustment bolt on bell housing.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n\u003cp\u003e\n\u003cspan\u003e\n\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\nDo not use with water that is unsafe or of unknown quality without adequate\ndisinfection either before or after the system.\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\n\u003ci\u003e\n\"Hydrate Everyone, Everywhere!\" BottleFillingStations.com |\n\u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e\nContact us\n\u003c\/a\u003e\n\u003c\/i\u003e\n\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914915418175,"sku":"12-600XLC","price":328.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/12-600XLC_AF.jpg?v=1771002802","url":"https:\/\/bottlefillingstations.com\/products\/zurn-wilkins-12-600xlc-12-water-pressure-reducing-valve-with-strainer","provider":"BottleFillingStations.com","version":"1.0","type":"link"}