{"product_id":"zurn-wilkins-114-500xlhr-water-pressure-reducing-valve-1-14-inches","title":"Wilkins 114-500XLHR | Water Pressure Reducing Valve, 1 1\/4 Inches","description":"\u003cp\u003e\u003cstrong\u003eNOTICE:\u003c\/strong\u003e\u003cem\u003e Product images may vary from the actual item due to differences in size or configuration options.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\nThe Wilkins 114-500XLHR is a high-performance water pressure reducing valve with integral by-pass check valve, designed for commercial and industrial water systems requiring reliable pressure control.\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eKey Specifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n    \u003cstrong\u003eSize:\u003c\/strong\u003e\n    1 1\/4 Inches\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eMaximum Working Pressure:\u003c\/strong\u003e\n    300 psi\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eMaximum Working Temperature:\u003c\/strong\u003e\n    140°F\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eNotable Certifications:\u003c\/strong\u003e\n    ASSE 1003, cUPC, CSA B356\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eConnection Type:\u003c\/strong\u003e\n    Single Union FNPT\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eOther Related Variants:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n    \u003cstrong\u003e112-500XLHR:\u003c\/strong\u003e\n    1\/2 Inches model size\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cstrong\u003e1-500XLHR:\u003c\/strong\u003e\n    1 Inches model size\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cstrong\u003e212-500XLHR:\u003c\/strong\u003e\n    2 1\/2 Inches model size\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cstrong\u003e2-500XLHR:\u003c\/strong\u003e\n    2 Inches model size\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cstrong\u003e3-500XLHR:\u003c\/strong\u003e\n    3 Inches model size\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eMaterials:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain valve body: Low Lead Cast Bronze ASTM B 584\u003c\/li\u003e\n  \u003cli\u003eAccess covers: Low Lead Cast Bronze ASTM B 584 \/ Low Lead Brass\u003c\/li\u003e\n  \u003cli\u003eFasteners: Stainless Steel, 300 series\u003c\/li\u003e\n  \u003cli\u003eStem \u0026amp; plunger: Low Lead Cast Bronze ASTM B 584 \/ Low Lead Brass\u003c\/li\u003e\n  \u003cli\u003eElastomers: Buna Nitrile (FDA approved) \/ EPDM (FDA approved)\u003c\/li\u003e\n  \u003cli\u003eCap gaskets: Natural vulcanized fibre \/ Acetal (Delrin™ 500)\u003c\/li\u003e\n  \u003cli\u003eSprings: Oil tempered wire, ASTM A 229\u003c\/li\u003e\n  \u003cli\u003eSeat: Stainless Steel, 300 series\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Installation:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nLocal codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. The assembly shall be installed with sufficient side clearance for testing and maintenance. The Model 500XL may be installed in any position. If installed in a pit, vault, or inside application, specify the \"SC\" sealed cage option. Multiple installations are recommended for wide demand variations or where the desired pressure reduction is more than 3 to 1 (i.e.: 150 psi inlet reduced to 50 psi outlet).\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"background: #f8f9fb; border-left: 4px solid #1d85af; padding: 12px 14px; margin: 0; line-height: 1.7; color: #333;\"\u003e\nASSE 1003; cUPC; CSA B356; City of Los Angeles; NSF\/ANSI\/CAN 61; NSF\/ANSI\/CAN 372\n\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eFeatures \u0026amp; Benefits:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Pressure Spring Range:\u003c\/strong\u003e The Zurn 114-500XLHR features HR Option with 75 to 125 psi spring range, factory set at 85 psi, ideal for applications requiring higher outlet pressures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Expansion Protection:\u003c\/strong\u003e Direct acting integral by-pass design prevents buildup of excessive system pressure caused by thermal expansion.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBalanced Piston Design:\u003c\/strong\u003e Provides smooth and responsive reaction to changes in system flow demand while protecting against inlet pressure fluctuations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersatile Installation:\u003c\/strong\u003e Can be installed in any position with single union connection for easier maintenance and serviceability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the pressure reduction range for the Wilkins 114-500XLHR?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The Zurn 114-500XLHR with HR option has a spring range of 75 psi to 125 psi and comes factory set at 85 psi. This makes it suitable for applications requiring higher outlet pressures compared to the standard 25-75 psi range.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can this valve be installed in any orientation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the Model 500XL can be installed in any position. However, if installed in a pit, vault, or inside application, you should specify the \"SC\" sealed cage option for optimal performance.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum recommended pressure reduction ratio?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Multiple installations are recommended where the desired pressure reduction is more than 3 to 1 ratio (e.g., 150 psi inlet reduced to 50 psi outlet). For greater reductions, consider a battery installation with multiple valves.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cdiv id=\"W3TucRPBpqQA9ARvwg6ni-content\"\u003e\n  \u003cp\u003e\n    \u003cspan\u003e\n      \u003cstrong\u003eNOTICE:\u003c\/strong\u003e\n      Do not use with water that is unsafe or of unknown quality without adequate\n      disinfection either before or after the system.\n    \u003c\/span\u003e\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\n  \u003ci\u003e\n    \"Hydrate Everyone, Everywhere!\" BottleFillingStations.com |\n    \u003ca rel=\"noopener\" href=\"https:\/\/bottlefillingstations.com\/pages\/contact-us\" target=\"_blank\"\u003e\n      Contact us\n    \u003c\/a\u003e\n  \u003c\/i\u003e\n\u003c\/p\u003e","brand":"Zurn Wilkins","offers":[{"title":"Default Title","offer_id":42914915188799,"sku":"114-500XLHR","price":1521.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/0985\/files\/1-500XL-01-01_49feb5c5-30bf-4fdd-b50e-e8d1d9af51ed.png?v=1770569052","url":"https:\/\/bottlefillingstations.com\/products\/zurn-wilkins-114-500xlhr-water-pressure-reducing-valve-1-14-inches","provider":"BottleFillingStations.com","version":"1.0","type":"link"}